ESCAPADE HEAVY DUTY & CONSTANT DUTY COMPACT OBA SYSTEMS
USER MANUAL
SPECIFICATIONS
• 50001 – Escapade Heavy Duty Compact OBA: 110/145 PSI (CE Certified)
Motor Voltage:
12-Volts
Max. Current Consumption:
30-Amps
Recommended Fuse:
40-Amps
Motor Type:
Permanent Magnetic
Horsepower:
1/4
Max. Working Pressure:
150 PSI
Max. Duty Cycle (@72°F & 100 PSI):
33%
min.tes On/Off (@72ºF & 100 PSI):
20 On/ 40 Off
Max. Ambient Temperature:
158°F
min. Ambient Temperature:
-40°F
Auto. Reset Thermal Protection:
Yes
Ingress Protection Rating:
IP67
• 50003 – Escapade Constant Duty Compact OBA: 110/145 PSI (CE Certified)
Motor Voltage:
12-Volts
Max. Current Consumption:
23-Amps
Recommended Fuse:
30-Amps
Motor Type:
Permanent Magnetic
Horsepower:
1/4
Max. Working Pressure:
150 PSI
Max. Duty Cycle (@72ºF & 100 PSI):
100%
min.tes On/Off (@72ºF & 100 PSI):
Continuous
Max. Ambient Temperature:
158°F
min. Ambient Temperature:
-40°F
Auto. Reset Thermal Protection:
Yes
Ingress Protection Rating:
IP67
ABOUT COMPRESSOR DUTY CYCLE:
Duty cycle refers to the amount of time a compressor can be
operated in a given time period at 100 PSI, and a standard ambient temperature of 72° F. It is
commonly expressed in percentage format: Compressor on time ÷ (on time + off time) = Duty Cycle%.
ONE-HOUR DUTY CYCLE
MINUTES ON /
(100 PSI @ 72°F)
MINUTES
OFF
9%
5 min. On / 55 min. Off
10%
6 min. On / 54 min. Off
15%
9 min. On / 51 min. Off
20%
12 min. On / 48 min. Off
25%
15 min. On / 45 min. Off
30%
18 min. On / 42 min. Off
33%
20 min. On / 40 min. Off
50%
30 min. On / 30 min. Off
100%
1 Hour Run Time
NOTE:
All compressors, regardless of rated duty cycle, require sufficient rest time in between cycles
to allow for partial or complete heat dissipation. Heat dissipation rates may vary depending on
ambient temperatures and operating conditions.
ABOUT RATED WORKING PRESSURE:
To ensure trouble free service life of your compressor, always operate compressor within rated
working pressure of the compressor. Never use a pressure switch with a higher cut-off pressure than
compressor's rated working pressure.