IMPORTANT SAFETY INSTRUCTIONS

CAUTION – 

To reduce risk of electrical shock 

or electrocution:

    Do   not   disassemble.   Do   not   attempt   repairs   or 

modifications. Refer to qualified service agencies for all 
service and repairs.

s

Do not use this product in or area where it can fall or be 

pulled into water or other liquids. 

p

Do not reach for this product if it has fallen into liquid. 

D

Use this compressor with 12-volt DC systems only. 

U

This   product   should   never   be   left   unattended   during 

use. 

WARNING – 

To prevent injury:

T

Never allow children to operate this compressor. Close 

supervision is necessary when this compressor is being 

used near children. 

u

This   compressor   will   become   very   HOT   during   and 

immediately   after   use.   Do   not   touch   any   part   of   this 

compressor   with   bare   hands,   other   than   the   ON/OFF 

switch, during and immediately after use. 

s

Do   not   use   this   product   near   flames   or   explosive 

materials or where aerosol products are being used. 

m

Do   not   operate   this   product   where   oxygen   is   being 

administered. 

a

Do not pump anything other than atmospheric air. 

D

Never use this product while sleepy or drowsy. 

N

Do   not   use   any   tools   or   attachments   without   first 

determining   maximum   air   pressure   for   that   tool   or 

attachment. 

a

Never point any air nozzle or air sprayer toward another 

person or any part of a person’s body. 

p

This   air   compressor   is   equipped   with   an   Automatic 

Reset Thermal Protector, and can automatically restart 

after   the   thermal   protector   resets.   Always   cut   off   the 

power   source   when   thermal   protector   becomes 

activated. 

a

Wear   safety   glasses   or   goggles   when   operating   this 

product. 

p

Use only in well ventilated areas. 

SAVE THESE INSTRUCTIONS

Summary of Contents for 44043-440P

Page 1: ...TABLE COMPRESSOR IMPORTANT It is essential that you and any other operator of the product read and understand the contents of this manual before installing and using this product SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL ...

Page 2: ...ch any part of this compressor with bare hands other than the ON OFF switch during and immediately after use s Do not use this product near flames or explosive materials or where aerosol products are being used m Do not operate this product where oxygen is being administered a Do not pump anything other than atmospheric air D Never use this product while sleepy or drowsy N Do not use any tools or ...

Page 3: ...ompressor rise above safe levels during excessive use 4 Should at any time during use your air compressor automatically shuts off do not attempt to restart Turn ON OFF switch of air compressor to the OFF position The automatic thermal overload protector will automatically reset when internal temperature of the air compressor drops below safe level After allowing air compressor to cool off for abou...

Page 4: ...Dust and Moisture Resistant but NOT DUST OR WATERPROOF Never place compressor in soft sand while running the compressor Vibration from the compressor will cause the compressor to settle into soft sand resulting in compressor drawing in foreign particles Never expose compressor to water while running the compressor IMPORTANT Make sure compressor sits upright while operating compressor Avoid tugging...

Page 5: ...HANDS FREE CONTINUOUS DEFLATION 1 Push the tire chuck with the lever in the upright position down over the tire valve stem and then push the lever down to the horizontal position to lock in place 2 Push Deflator Collar toward tire valve stem and turn Deflator Collar clockwise to engage lock 3 When desired pressure if reached turn Deflator Collar counterclockwise to disengage lock C INTERMITTENT DE...

Page 6: ...ressure buildup if the tire chuck is not attached to tire valve stem while air compressor is in operation 7 IMPORTANT Always use an Open Ended tire chuck such as the tire chuck equipped on the Inflator Deflator Coil Hose for tire inflation CAUTION Never touch the air compressor or fittings connected to the air compressor with bare hands during or immediately after use The fittings on extension hos...

Page 7: ... Compressor will not run 1 No power or switch in OFF position 1 Make sure compressor switch is ON 2 Blown fuse 2 Disconnect compressor from power source replace fuse Refer to Specifications section for correct fuse 3 Motor overheats 3 Let compressor cool off for about 30 minutes to allow thermal overload reset Thermal Overload Protector cuts out repeatedly 1 Lack of proper ventilation or ambient t...

Page 8: ...nd conditions of the retailer s policy for exchanges If you are unable to contact your dealer contact VIAIR directly for repairs or replacement at our option PLEASE NOTE THIS WARRANTY COVERS PRODUCT DEFECTS ONLY IT DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES AS RESULT OF MISUSE OR ABUSE ...

Reviews: