VIAIR COMPRESSOR REFERENCE CHART

COMPRESSOR SERIES 

MAX. WORKING 

DUTY CYCLE

 

PRESSURE   

(100 PSI @ 72°F)

090 SERIES 

120 PSI  

9%  

 

092 SERIES 

120 PSI  

9%  

095 SERIES 

120 PSI  

9%  

097 SERIES 

130 PSI  

10%  

098 SERIES 

130 PSI  

10%  

100 SERIES 

130 PSI  

15%  

250 IG SERIES 

150 PSI  

100%  

275 SERIES 

150 PSI  

25%  

280 SERIES 

150 PSI  

30%  

325 SERIES 

150 PSI  

33%  

330 IG SERIES 

150 PSI  

100%  

350 SERIES 

150 PSI  

100%  

380 SERIES 

200 PSI  

100%      

 

 

55% @ 200 PSI

400 SERIES 

150 PSI  

33%  

420 SERIES 

150 PSI  

33%  

425 SERIES 

175 PSI 

    33% @ 175 PSI 

 

 

 

50%

444 SERIES 

200 PSI  

100%     

 

 

50% @ 200 PSI

450 SERIES 

150 PSI  

100%  

450 IG SERIES 

150 PSI  

100%  

460 SERIES 

150 PSI  

100%  

480 SERIES 

200 PSI  

100%  

 

 

 

50% @ 200 PSI

485 SERIES 

200 PSI  

100%  

 

 

 

100% @ 200 PSI

ABOUT COMPRESSOR DUTY CYCLE:

Duty cycle refers to the amount of time a compressor can be
operated in a given time period at 100 

PSI, and a standard ambient temperature of 72° F. It is commonly expressed in percentage format: 

Compressor on time ÷ (on time + off time) = Duty Cycle %.

ONE-HOUR DUTY CYCLE   

MINUTES ON / 

(100 PSI @ 72°F) 

  MINUTES 

OFF

  9% 

5 Min. On / 55 Min. Off

  10% 

6 Min. On / 54 Min. Off

  15% 

9 Min. On / 51 Min. Off

  20% 

12 Min. On / 48 Min. Off

  25% 

15 Min. On / 45 Min. Off 

  30% 

18 Min. On / 42 Min. Off

  33% 

20 Min. On / 40 Min. Off

  50% 

30 Min. On / 30 Min. Off

100%                                                     1 Hour Run Time

NOTE: All compressors, regardless of rated duty cycle, require sufficient rest time in between cycles 

to allow for partial or complete heat dissipation. Heat dissipation rates may vary depending on 

ambient temperatures and operating conditions.

ABOUT RATED WORKING PRESSURE:

To ensure trouble free service life of your compressor, always operate compressor within rated 

working pressure of the compressor.  Never use a pressure switch with a higher cut-off pressure than 

compressor’s rated working pressure. 

Summary of Contents for 400H-A

Page 1: ...t read and understand the contents of this manual before installing and using this product SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL 400H A HARDMOUNT AUTOMATIC AIR COMPRESSOR KIT PART NO 40041 450H A HARDMOUNT AUTOMATIC AIR COMPRESSOR KIT PART NO 45041 450H A 400H A ...

Page 2: ...r even inside your vehicle The compact size of this compressor requires minimal space and oil less design permits mounting in many different areas of your vehicle Please read and follow these Installation Instructions carefully to avoid injury or damage to the compressor or to your vehicle Each of our air compressors and parts have been carefully produced and packaged Before you begin installation...

Page 3: ...r Compressor Kit USER MANUAL A C D E G H I F B C C D E F Fig 2 Compressor Mounting Hardware B Mounting Bolt C Flat Washer D Locking Washer E Nut F Vibration Isolator J B OPERATING INSTRUCTIONS 1 IMPORTANT Always operate the compressor at or below the MAXIMUM PRESSURE RATING of the compressor Please refer to Application Specifications Sections of this manual for details 2 Always observe the MAXIMUM...

Page 4: ...sh the lever down to the horizontal position to lock in place 3 Turn compressor switch on and hold down the trigger on the tire gun kit to begin inflation TIRE DEFLATION 1 Push the tire chuck with the lever in the upright position down over the tire valve stem and then push the lever down to the horizontal position to lock in place 2 Press the bleeder valve button on the tire gun kit to decrease t...

Page 5: ...airs should be performed by Manufacturer or Manufacturer s Authorized Service Agencies only CAUTION Never touch the air compressor or fittings connected to the air compressor with bare hands during or immediately after usage If necessary wear heat resistant gloves to handle fittings air line and coil hose SPECIFICATIONS Part No 40041 400H A Automatic Air Compressor Motor Voltage 12 Volts Max Curre...

Page 6: ...SI 100 100 200 PSI ABOUT COMPRESSOR DUTY CYCLE Duty cycle refers to the amount of time a compressor can beoperated in a given time period at 100 PSI and a standard ambient temperature of 72 F It is commonly expressed in percentage format Compressor on time on time off time Duty Cycle ONE HOUR DUTY CYCLE MINUTES ON 100 PSI 72 F MINUTES OFF 9 5 Min On 55 Min Off 10 6 Min On 54 Min Off 15 9 Min On 51...

Page 7: ...wer source replace fuse Refer to Specifications section for correct fuse amperage 3 Let compressors cool off for about 30 minutes to allow thermal overload switch to reset 4 Replace pressure switch Thermal overload protector cuts out repeatedly 1 Lack of proper ventilation or ambient temperature is too high 2 Compressor valves failed 1 Move compressor to well ventilated area or area with lower amb...

Page 8: ...WARRANTY COVERS PRODUCT DEFECTS ONLY IT DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES AS RESULT OF MISUSE OR ABUSE This Manual is proprietary to VIAIR Corporation and no ownership rights are hereby transferred No part of the Manual shall be used reproduced translated converted adapted stored in a retrieval system communicated or transmitted by any means for any commercial purpose including wi...

Reviews: