background image

IMPORTANT SAFETY INSTRUCTIONS:

CAUTION: To reduce risk of electrical shock or electrocution:

-  Do not disassemble. Do not attempt repairs or modifications. 

  Refer to qualified service agencies for all service and repairs.

-  Do not use this product in or area where it can fall or be pulled into water or other liquids.

-  Do not reach for this product if it has fallen into liquid.

-  Use this compressor with 12-volt DC systems only.

-  This product should never be left unattended during use.

WARNING: To prevent injury:

-  Never allow children to operate this compressor. 

  Close supervision is necessary when this compressor is being used near children.

-  This compressor will become very HOT during and immediately after use. 

  Do not touch any part of this compressor with bare hands, other than the ON/OFF switch 

  during and immediately after use.

-  Do not use this product near flames or explosive materials or where aerosol products 

  are being used.

-  Do not operate this product where oxygen is being administered.

-  Do not pump anything other than atmospheric air.

-  Never use this product while sleepy or drowsy.

-  Do not use any tools or attachments without first determining maximum air pressure for that 

  tool or attachment.

-  Never point any air nozzle or air sprayer toward another person or any part of the body.

-  This air compressor is equipped with an Automatic Reset Thermal Protector, and can    

  automatically restart after the thermal protector resets. Always cut off power source when 

  thermal protector becomes activated.

-  Wear safety glasses or goggles when operating this product.

-  Use only in well ventilated areas.

OPERATING INSTRUCTIONS:

Please read and follow the operating instructions carefully to assure that you will enjoy the 

convenience and best use out of your air compressor.

1. Always operate the compressor AT OR BELOW THE MAXIMUM PRESSURE RATING of the  

  compressor. Refer to Specifications section of this manual.

2. Always OBSERVE THE MAXIMUM DUTY CYCLE of the air compressor. Refer to Specifications  

  section of this manual for details. Operations exceeding maximum pressure ratings and or duty  

  cycle will result in damage to air compressor.

3. Your air compressor is equipped with an AUTOMATIC THERMAL OVERLOAD PROTECTOR. 

  This feature is designed to protect the air compressor from overheating causing permanent  

  damage to your air compressor. The thermal overload protector will automatically cut off power  

  to air compressor should internal operating temperature of the air compressor rise above safe  

  levels during excessive use.

4. Should at any time during use, your air compressor automatically shuts off, do not attempt to  

  restart air compressor. Turn ON/OFF switch of air compressor to the OFF position. The automatic  

  thermal overload protector will automatically reset when internal temperature of the air  

  compressor drops below safe level. After allowing air compressor to cool off for about 30 minutes,  

  you can safely resume use of the air compressor by turning on the air compressor.

5. Please note that you may experience a slight delay (about ½ second) of the compressor’s motor  

  starting when the On/Off Switch is turned on while compressor is pressurized (when there is  

  pressure in the line that the compressor is connected to). This is a normal delayed reaction, not a  

  Compressor ON/OFF switch malfunction.

6. It is strongly recommended that you keep the vehicle’s engine running while using the air 

  compressor to prevent discharge of your vehicle’s battery.

7. ONLY OPERATE THE AIR COMPRESSOR IN WELL VENTILATED AREAS. 

  Compressor performance is enhanced when operating compressor with vehicle engine running.

USER MANUAL

400P PORTABLE COMPRESSOR

Summary of Contents for 40043

Page 1: ... and any other operator of this product read and understand the contents of this manual before installing and using this product SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL 400P PORTABLE COMPRESSOR HEAVYWEIGHT SERIES PART NO 40043 ...

Page 2: ...nce and best use out of your air compressor 1 Always operate the compressor AT OR BELOW THE MAXIMUM PRESSURE RATING of the compressor Refer to Specifications section of this manual 2 Always OBSERVE THE MAXIMUM DUTY CYCLE of the air compressor Refer to Specifications section of this manual for details Operations exceeding maximum pressure ratings and or duty cycle will result in damage to air compr...

Page 3: ...sor switch on to begin inflation When desired pressure is reached turn compressor off CAUTION To avoid over inflation never exceed recommended pressure on articles to be inflated Bursting can cause serious injury HANDS FREE CONTINUOUS DEFLATION 1 Push the tire chuck with the lever in the upright position down over the tire valve stem and then push the lever down to the horizontal position to lock ...

Page 4: ...r air compressor is equipped with permanently lubricated maintenance free motor Never try to lubricate the compressor Regularly clean dust and dirt from compressor cooling fins and motor housing All repairs should be performed by Manufacturer or Manufacturer authorized service agencies only MODEL 400P SPECIFICATIONS Part Number 40043 400P Motor Voltage 12 volt Motor Type Permanent Magnetic Max Int...

Reviews: