200 PSI FAST-FILL AIR SOURCE KIT

USER MANUAL

COMPRESSOR APPLICATION GUIDE:

ABOUT COMPRESSOR DUTY CYCLE:

Compressor Duty Cycle refers to amount of time a compressor 

can be operated in a given time period, at 100 PSI & at a 

standard ambient temperature of 72°F. 

Duty Cycle is commonly expressed as:

Compressor On Time / (Compressor On Time + Off Time)

As an example, a compressor that is rated for 20% duty cycle 

means that compressor can be operated at 100 PSI @ 72°F 

for 8 Minutes and rested for 32 Minutes.

8 min. on / (8 min. on + 32 min. off) = 20% Duty Cycle

DUTY CYCLE REFERENCE CHART

DUTY CYCLE @100PSI / 72°F 

MINUTES ON / OFF

15% 

6 Min. On / 34 Min. Off

17% 

7 Min. On / 30 Min. Off

20% 

8 Min. On / 32 Min. Off

22% 

9 Min. On / 30 Min. Off

25% 

10 Min. On / 30 Min. Off 

30% 

13 Min. On / 30 Min. Off

33% 

15 Min. On / 30 Min. Off

100% 

Continuous Duty

ABOUT RATED WORKING PRESSURE:

To ensure trouble free service life of your compressor, always 

operate compressor within rated working pressure of the 

compressor.  Never use a pressure switch with a higher 

cut-off pressure than compressor’s rated working pressure. 

SPECIFICATIONS:

380C AIR COMPRESSOR

Motor Voltage: 

12 Volts 

Max. Current Consumption: 

16 Amps 

Recommended Fuse:                              20 Amps

Motor Type: 

Perm. Magnetic

Horse Power: 

1/4

Max. Working Pressure: 

200 PSI

Max. Duty Cycle (@72°F & 100 PSI): 

100%

Max. Duty Cycle (@72°F & 200 PSI): 

55%

Max. Restart Pressure: 

200 PSI 

Max. Ambient Temperature: 

158°F

Min. Ambient Temperature: 

-40°F

Auto. Reset Thermal Protection: 

Yes

Summary of Contents for 20003

Page 1: ...tor of this product read and understand the contents of this manual before installing and using this product SAVE THIS MANUAL FOR FUTURE REFERENCE Only Compressor is CE Certified 200 PSI FAST FILL AIR SOURCE KIT 55 Duty Compressor on 2 0 Gallon Air Tank PART NO 20007 ...

Page 2: ...h any part of this compressor with bare hands other than the ON OFF switch during and immediately after use Do not use this product near flames or explosive materials or where aerosol products are being used Do not operate this product where oxygen is being administered Do not pump anything other than atmospheric air Never use this product while sleepy or drowsy Do not use any tools or attachments...

Page 3: ... possible so that length of positive lead wire required is at a minimum 3 Choose mounting location that is as cool as possible and AWAY FROM HEAT SOURCES The cooler the ambient temperature the less chance the compressor will overheat 4 The compressor is moisture splash resistant but NOT WATERPROOF Do not mount air source kit in locations where the unit is likely to come in contact with water 5 If ...

Page 4: ...line connection Tighten compression fitting nut securely using a wrench 6 Connect ground Black wire to a clean ground preferably a chassis ground and secure with a self tapping screw 7 Connect positive Red lead wire from pre installed pressure switch to a fuse holder 20 amp minimum 8 Once the kit is properly fused as close as possible to the power source connect and test compressor system by runni...

Page 5: ...ill automatically cut off power to your air compressor should the internal operating temperature of the air compressor rise above safe levels during excessive use 4 Should at any time during use your air compressor automatically shuts off do not attempt to restart air compressor Turn power switch to the air compressor to the OFF position The automatic thermal overload protector will automatically ...

Page 6: ... Drain water from tank by opening the drain cock drain valve c If drain cock is plugged release all air pressure from tank remove drain valve and clean then reinstall d After condensate has been drained close the drain cock IMPORTANT Observe air tank Date of Manufacture stamped on tank leg Replace air tank 2 to 5 years from date air tank was first used or use the date of manufacture as reference Y...

Page 7: ...in On 34 Min Off 17 7 Min On 30 Min Off 20 8 Min On 32 Min Off 22 9 Min On 30 Min Off 25 10 Min On 30 Min Off 30 13 Min On 30 Min Off 33 15 Min On 30 Min Off 100 Continuous Duty ABOUT RATED WORKING PRESSURE To ensure trouble free service life of your compressor always operate compressor within rated working pressure of the compressor Never use a pressure switch with a higher cut off pressure than ...

Page 8: ...normal 1 Excessive air usage 2 Loose connections 3 Worn piston ring or inlet valve 4 Clogged air filter element 1 Decrease air usage 2 Check all connections wit soap and water solution and tighten 3 Repair or replace compressor 4 Replace air filter element Compressor runs continuously causing safety valve if equipped to open 1 Bad pressure switch 2 Defective safety valve 1 Replace pressure switch ...

Page 9: ...ct fuse amperage 3 Let compressors cool off for about 30 Minutes to allow thermal overload switch reset 4 Replace pressure switch Thermal overload protector cuts out repeatedly 1 Lack of proper ventilation or ambient temperature too high 2 Compressor valves failed 1 Move compressor to well ventilated area or area with lower ambient temperature 2 Repair or replace compressor Excessive knocking or r...

Page 10: ...e contact VIAIR Corporation Returns should be made within one year of the date of purchase after a Return Goods Authorization RGA number has been assigned by VIAIR Corporation To obtain RGA fax a copy of your receipt to 949 585 0188 For complete warranty details please visit www viaircorp com warranty PLEASE NOTE THIS WARRANTY COVERS PRODUCT DEFECTS ONLY IT DOES NOT COVER INCIDENTAL OR CONSEQUENTI...

Reviews: