275C OPERATING INSTRUCTIONS

IMPORTANT: The 275C has a maximum working pressure of 150. Always operate the compressor at or below 

the MAXIMUM PRESSURE RATING of the compressor. Exceeding maximum pressure ratings and duty cycle 

may damage air compressor.  

1. Your air compressor is equipped with an AUTOMATIC THERMAL OVERLOAD PROTECTOR.  

  This feature will protect the air compressor from overheating and causing permanent damage to your air  

 

  compressor. The thermal overload protector will automatically cut off power to your air compressor should  

  the internal operating temperature of the air compressor rise above safe levels during excessive use. 

2. Should your air compressor automatically shut off during use, turn power to the system off. The automatic  

  thermal overload protector will automatically reset when internal temperature of the air compressor drops    

  below safe levels.  After allowing air compressor to cool off for about 30 minutes, you can safely resume use  

  of the air compressor by turning on the system.

3. To prevent discharge of your battery and to provide peak performance, it is recommended that you keep 

  the engine running while the air compressor is in use. 

4. ONLY OPERATE THE AIR COMPRESSOR IN WELL-VENTILATED AREAS. 

275C Compressor Maintenance & Repairs:

1. Periodically check all electrical and fitting connections.  Clean and tighten as needed.  

2. Periodically check all mounting screws. Tighten as needed.

3. Replace air filter element periodically. Replacement frequency depends on operating frequency and  

 

  operating environment. For frequent use in dusty environment, you should replace air filter element 

  more often.  

4. Regularly clean dust and dirt from compressor.

5. Your air compressor is equipped with permanently lubricated, maintenance-free motor. 

    Never lubricate compressor.

6. Repairs should be performed by Manufacturer or Manufacturer’s Authorized Service Agencies only.  

CAUTION: Never touch the air compressor or fittings connected to the air compressor with bare hands during 

or immediately after use. Leader hose and fittings will become very HOT during and after use.

275C Compressor Installation Tips:

1. Always use the remote intake filter option when possible. This will extend the service life of your compressor. 

2. If noise reduction from vibration is desired, using the remote mount option for the inlet filter can reduce  

 

  operation noise by up to 25%.    

3. Always mount the compressor at a point higher than the inlet port of the tank. 

  This will keep moisture from being able to seep back to the tank.

4. When mounting the compressor, use a paint pen on the rubber isolators and cover the side to go against the  

  chassis or mounting location. Then, simply stamp the compressor against the chassis to make an imprint of  

  exactly where to drill the mounting holes for the compressor. 

USER MANUAL

QUARTER DUTY ONBOARD AIR SYSTEM

Summary of Contents for 10002

Page 1: ...TEM PART NO 10002 IMPORTANT It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL ...

Page 2: ...your vehicle Please follow these instructions to install your new system OBA Components 1 2 0 Gallon 5 port VIAIR Air Tank 1 275C model VIAIR compressor with leader hose and check valve Check to make sure that you have six labeled packages in your kit Each package contains the parts needed for specific areas of installation and may contain smaller bags within each package for specific uses PARTS P...

Page 3: ... YOU HAVE INSTALLED ALL NECESSARY PORT FITTINGS AND ACCESSORIES Apply sealant to threads of fittings prior to assembly and tighten each part with a wrench Do not over tighten if your port fittings are made from brass since brass threads can be stripped Always release air from tank before servicing WARNING FAILURE TO DRAIN TANK AND REMOVE CONDENSATION WILL CAUSE TANK TO RUST PREMATURELY To remove a...

Page 4: ...lon tape is not recommended Properly sealed recommended torque is 12 to 15 ft lbs 275C Compressor Wiring See Figure 3 on back of manual 1 Disconnect ground cable from vehicle s battery 2 Temporarily position the air compressor in the location where it will be mounted 3 Route ground wire to the negative post of the battery or to an appropriate grounding point and cut ground wire to length as needed...

Page 5: ...onnections Clean and tighten as needed 2 Periodically check all mounting screws Tighten as needed 3 Replace air filter element periodically Replacement frequency depends on operating frequency and operating environment For frequent use in dusty environment you should replace air filter element more often 4 Regularly clean dust and dirt from compressor 5 Your air compressor is equipped with permane...

Page 6: ...es heat sources and tight bends Air line must be routed at least 12 inches from exhaust systems other heat sources IMPORTANT Drilling through firewall Always be sure of what is on the other side of the firewall before drilling Take care not to damage your vehicle s electronic systems or components Wiring an ON OFF Switch Using a relay Run a wire to a simple two position switch that can be mounted ...

Page 7: ... tank to drain Drain tank more frequently 2 Move compressor to area with less humidity or use air line filter Compressor will not run 1 No power or power switch in OFF position 2 Blown fuse 3 Motor overheats 4 Faulty pressure switch 1 Make sure compressor switch is ON 2 Disconnect compressors from power source replace fuse Refer to Specifications section for correct fuse amperage 3 Let compressors...

Page 8: ...ormal conditions of use to be free from defects in workmanship and materials for a period of one year from its original date of purchase To receive warranty service or repair please contact VIAIR Corporation Returns should be made within one year of the date of purchase after a Return Goods Authorization RGA number has been assigned by VIAIR Corporation To obtain RGA fax a copy of your receipt to ...

Reviews: