Vexar 368STM-1 Owners & Installation Manual Download Page 2

www.fmiproducts.com

56149J

2

SaFeTy

 CAUTION: The structural integ-

rity of the mobile home floor and 

ceiling/roof must be maintained.

 WARNING: Do not install a 

fireplace insert in this box unless 

the manufacturer's instructions 

with the insert specifically state 

this fireplace has been tested for 

use with the insert.
FOR YOUR SAFETY

•  Do not store or use gasoline 

or any other flammable vapors 

or liquids in the vicinity of this 

or any other appliance.

•  Due to high temperatures, the 

appliance  should  be  located 

out  of  traffic  and  away  from 

furniture and draperies.

•  Do not place clothing or other 

flammable materials on or near 

the appliance.

•  Never  leave  children  unat-

tended when a fire is burning 

in the fireplace.

This fireplace is not intended to 

be used as a substitute for a fur-

nace to heat an entire home. Use 

for supplemental heat only.

This wood burning fireplace com-

plies with the UL 127 standard as 

a FACTORY BUILT FIREPLACE.

This fireplace meets construc-

tion  and  safety  standards  of 

HUD  for  application  in  mobile 

homes when installed according 

to these directions.

 WARNING: Improper in-

stallation, adjustment, altera-

tion, service or maintenance 

can  cause  injury,  property 

damage or loss of life. Refer 

to this manual for assistance 

or  additional  information. 

Consult a qualified installer 

or local distributor.

IMPORTANT:  Check  HUD  re-

quirements before installing this 

fireplace.

Model 368STM is specifically designed for use 

in manufactured mobile homes. This fireplace 

includes a manual control fan system, com

-

bustion air kit and bi-fold doors.
Before beginning installation of fireplace, read 

these instructions through completely.

•  This Style Crest, Inc. fireplace and its com

-

ponents are safe when installed according 

to this installation manual. Unless you use 

Style Crest, Inc. components, which have 

been  designed  and  tested  for  fireplace 

system, you may cause a fire hazard.

•  The Style Crest, Inc. warranty will be voided 

by and Style Crest, Inc. disclaims any re

-

sponsibility for the following actions.

a. Modification of fireplace, components, 

doors, blower, fans, air inlet system and 

damper control.

b. Use of any component part not manu

-

factured  or  approved  by  Style  Crest, 

Inc. in combination with a Style Crest, 

Inc. fireplace system.

Proper installation is the most important step 

in  ensuring  safe  and  continuous  operation 

of fireplace. Consult local building codes as 

to  the  particular  requirements  concerned 

with installation of all factory built fireplaces. 

Although grounding may not be required by 

code, the manufacturer recommends it.

Table oF conTenTS

Safety ..................................................................

2

Specifications ......................................................

3

Fireplace Installation............................................

3

Venting Installation ..............................................

6

Optional Gas Line Installation............................

12

Operation and Maintenance ..............................

13

Accessories .......................................................

14

Replacement Parts ............................................

16

Technical Service...............................................

16

Summary of Contents for 368STM-1

Page 1: ...free log can only be installed in an aftermarket completion of sale not for purpose of resale from the manufacturer permanently located manufactured mobile home where not prohibited by local codes A...

Page 2: ...or local distributor IMPORTANT Check HUD re quirementsbeforeinstallingthis fireplace Model 368STM is specifically designed for use in manufactured mobile homes This fireplace includes a manual contro...

Page 3: ...ill make installation easier 4 An outside air kit is available with this fireplace see Outside Air Kit on page 5 WARNING Donotinstallthis appliance in a bedroom 24 37 1 2 20 1 2 10 1 4 53 1 2 17 1 2 4...

Page 4: ...the full width and depth of fireplace 3 Set fireplace directly in front of opening and slide unit back until nailing flanges touch side framing 4 Check level of fireplace and shim with sheet metal if...

Page 5: ...means to prevent hearth extension from shifting and seal gap between fireplace frame and hearth extension with a noncombustible material see Figure 3 WARNING Hearthextension is to be installed only a...

Page 6: ...tion air is accessed through mobile home floor using air kit modelAK 6 or a side wall using air kit model AK 6WI see Accessories on page 14 CAUTION Combustion air inlet ducts shall not terminate in a...

Page 7: ...mble to firestop spacer An opening large enough to allow insertion of firestop thimble assembly will be required in the ceiling Attach firestop thimble assembly to ceiling ceiling joist using screws o...

Page 8: ...mum of 36 above high est point where it passes through roof 16 3 8 Min 48 3 cm 30 Min 76 cm 2 Min 5 1 cm 2 Min 5 1 cm 2 Min 5 1 cm Opening A PITCH SLOPE OPENING A MAX FLASHING MODE NO Flat 0 17 6F 8 0...

Page 9: ...4 46 1 4 1 23 3 4 49 1 4 1 1 27 3 4 56 3 4 1 30 60 3 4 1 1 33 66 1 1 36 71 1 1 38 1 4 75 2 41 1 4 80 1 4 1 1 1 45 86 3 4 2 46 3 4 89 1 2 1 1 1 51 97 1 1 53 1 4 101 2 1 56 1 4 106 1 4 2 59 1 4 111 1 2...

Page 10: ...ions with slip sections Note Storm collar is required but can be installed after home is sited Figure 16 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing Terminations Spark Arrestor Th...

Page 11: ...al distance of 10 feet see Figure 19 10 2 Min 10 3 Min 2 Min 3 Min Level of Flue Gas Outlet Figure 19 10 Foot Rule Chimney Support Bracket Kit CSK 8DM If exposed portion of chimney is greater than fiv...

Page 12: ...nt free appliance available through your local distributor Use only a 1 2 black iron pipe and appropriate fittings When installing a gas line a shutoff valve designed for installation outside the appl...

Page 13: ...place When fireplace is in operation doors must be FULLY OPENED or FULLY CLOSED position only or a fire hazard may be created see Figure 23 A fireplace equipped with glass doors operates much differen...

Page 14: ...ll to close and push to open Always open both handles before starting a fire This provides adequate outside combus tion air Close both handles when not in use to prevent cold air from entering the roo...

Page 15: ...144 96 12 30 AccessorIES Continued SQUARE CHASE TOP TERMINATION ETL 8DM Optional OUtside air kit for side wall installation AK 6WI Hearth extension he 36 Thimble extensions TXL 8DM 43 TX 8DM 26 Vent...

Page 16: ...have further questions about installation operation or troubleshooting If so contact Style Crest Inc at 1 800 231 4822 or write to Style Crest Service P O Box 19110 Wichita KS 67204 When calling or wr...

Reviews: