10
370801.01
vetus®
User manual E-POD electric propulsion
4
Take out of service -
prepare for winter
Follow the instructions below if the E-POD motor is to be taken out
of service for a long time. Long-term means a period longer than 3
months, for example during the winter period.
Make sure the motor compartment is ventilated. Good ventilation
prevents moisture in the motor compartment. This prevents corro-
sion.
Carry out the necessary maintenance work before taking the motor
out of service for a long time. Checks and maintenance work to be
carried out:
• Clean the motor with a cloth.
n
ote
The cover plate of the E-POD motor is splashproof .
• Disconnect the batteries, fully charge them and grease the bat-
tery terminals. Store the batteries in a dry and frost-free place.
4 .1 Electrical System
• If necessary, regularly charge the batteries during the winter!
• For checking and maintenance of the batteries, follow the recom-
mendations of the battery supplier.
5
Put into service - prepare for summer
When putting the motor back into service, for example at the begin-
ning of the boating season, the motor must be checked and mainte-
nance work carried out.
• Check and reconnect the batteries.
• Check the operation of the motor.
• Check the operation of the instruments and motor controls.
5 .1 Electrical system
• Check the voltage of each individual battery. In case of large volt-
age deviations, the batteries should be charged separately.
• Connect the batteries and fully charge the 48 volt battery bank.
5 .2 Test run
W
arninG
Only test the E-POD motor if you are sure that people are at a
safe distance from the propeller!
• Switch on the E-POD motor and check correct operation.
• Also check the operation of the connected panels.
6
Troubleshooting
Malfunctions of the E-POD motor are in most cases caused by incor-
rect operation or insufficient maintenance.
In the event of a malfunction, always first check whether all operating
and maintenance instructions have been followed.
If you are unable to determine the cause of a fault or rectify a fault
yourself, please contact the nearest service representative.
D
anGer
Before starting, make sure that nobody is in the immediate
vicinityof the motor .
If necessary, disconnect the battery cables!
E-POD motor does not run
Possible cause
Solution
Defective or discharged battery.
Check / recharge battery and
check battery charger.
Fuse burned out.
Check the system. Replace
the fuse. If a replacement fuse
blows again, this indicates an
electrical problem. Have the
system checked by an installer.
Loose or corroded connections
in the starter circuit.
Clean and secure the connec-
tions.
Poor electrical connection.
Repair.
Defective starter switch.
Check / replace.
Jammed parts.
Repair.
Short circuit due to reverse polar-
ity.
Irreparable damage to motor
controller. Replace MCVB and all
connected panels.
ENGLISH