Vetus-Maxwell 6000 24V DC Manual Download Page 14

12 

one  of  our  distributors  worldwide  (Appendix  D). 
When ordering spare parts, please quote: 

• 

Capstan model

 

• 

Serial number of the capstan

 

• 

Part number (see Appendix B) 

• 

Part description

 

• 

Quantity required

 

 
 

4.4  

TOOLS FOR MAINTENANCE 

 

We recommend the following tools be kept on board 
for disassembling and assembling the capstan: 

• 

Set of metric hexagon keys (Allan keys), sizes  8 

and 10mm

 

• 

Ring  /  open  end  spanner  17mm,  19mm  and 

24mm

 

• 

Flat screwdriver 10mm blade width

 

• 

Circlip pliers

 

 
 

 

 

 

 

 

Summary of Contents for 6000 24V DC

Page 1: ...CAPSTAN 6000 SERIES...

Page 2: ...d All rights reserved Printed in New Zealand P101026 Rev 9 00 19 11 2018 VETUS Maxwell APAC Ltd reserves the right to make engineering changes to all products without notice Illustrations and specific...

Page 3: ...TIONS TO AC MOTOR 7 2 7 POWER CONNECTIONS TO DC MOTOR 7 2 8 POWER CONNECTIONS TO HYDRAULIC MOTOR 8 2 9 INSTALLATION OF CONTROLS 8 2 10 NOTE TO BOAT BUILDER 8 3 0 USING THE CAPSTAN 9 3 1 PERSONAL SAFET...

Page 4: ...ell distributor The connection of the power lines and control circuitry to the capstan must be done by skilled technicians to ensure reliable and safe operation of the capstan Although mooring capstan...

Page 5: ...Weight of capstan dual speed 181kg 398lb Hydraulic Drive Line speed at recommended flow 14 m min 46 ft min Recommended hydraulic oil flow 48 l min 12 7 USgal min Maximum hydraulic oil flow 88 l min 2...

Page 6: ...the motor and full protection for the supply cables It also provides the means for isolating the electrical system from the battery This should be mounted in a dry place within 1 8m 72 of cable length...

Page 7: ...hers Remove deckplate Refer to Appendix B of this Manual and identify all parts If any parts are damaged or missing contact your Maxwell distributor Some smaller parts might not be assembled on the ca...

Page 8: ...perienced persons familiar with anchoring procedures and the vessels generating capacity Direct On Line starter is the simplest way of starting an AC motor and it will allow the windlass to start unde...

Page 9: ...ke the line connections to motor terminals Make also an effective earth connection Separately and similarly enter the 2 thermistor cables to the motor terminal box and connect to the two auxiliary ter...

Page 10: ...y stepping on a footswitch Refer to wiring schematics in Appendix C for control circuits All control wiring should be done using no smaller than 1 5mm wire AWG 16 A manually re settable ignition proof...

Page 11: ...r for main power supply and the isolator for footswitches Wrap several turns of line around the drum Make sure the drum is operated in the same direction as the line is wrapped around it Whilst pullin...

Page 12: ...ray them with CRC 3037 Long Life or alternatively with CRC 6 66 or WD 40 Regular use of CRC3097 Long Life will assist in maintaining the bright chrome finish Apply anti seize compound on screw threads...

Page 13: ...fore applying the new one 4 3 SPARE PARTS Maxwell recommends a modest quantity of spare parts to be ordered as familiarity with the capstan is developed during installation As small parts can be lost...

Page 14: ...Part number see Appendix B Part description Quantity required 4 4 TOOLS FOR MAINTENANCE We recommend the following tools be kept on board for disassembling and assembling the capstan Set of metric he...

Page 15: ...istance between terminals 21 and 22 If it is above 500 ohms contact Maxwell No power supply to the capstan Check power supply lines Check main isolator switch Check hydraulic pump Capstan is not able...

Page 16: ...14 APPENDIX A Dimensional Drawings...

Page 17: ...15...

Page 18: ...16 APPENDIX B Spare Parts Topworks...

Page 19: ...etaining clip 2 2689 9 Deck seal 1 SP0719 10 Deck bearing 1 3004 11 Hex Hd Bolt Standard clearance M12 x 70 stainless steel 100mm extra deck clearance M12 x 170 stainless steel 8 8 SP3201 SP3217 12 Sp...

Page 20: ...18 Spare Parts Bottomworks...

Page 21: ...ic AC 208V 60Hz Electric AC 400V 50Hz 220V 50Hz Electric AC 440V 60Hz 2 speed Electric AC 400V 50Hz 2 speed Electric AC 208V 60Hz 2 speed Hydraulic 1 1 1 1 1 1 1 SP2993 SP3367 SP3325 SP4118 SP3335 SP3...

Page 22: ...20 APPENDIX C Installation Schematics...

Page 23: ...21...

Page 24: ...22...

Page 25: ...23...

Page 26: ...l not be liable for any loss damages harm or claim attributed to a use of the products in applications for which the products are not intended b corrosion wear and tear or improper installation c impr...

Page 27: ...ler or supplier of the goods or fill out the electronic warranty form on our website www maxwellmarine com Name Address Telephone Facsimile Supplier Dealer Name Address Telephone Facsimile Windlass Mo...

Page 28: ...26...

Reviews: