CORPORATE PRESENTATION
Compressor Replacement
Procedure of compressor switch.
1: WARNING! Drain coolant R600a from refrigeration system by vacuum suction
2: IMPORTANT! Blow refrigeration system with NO/Nitrogen
3: Cut
A: Suction and pressure tube
B: Capillary tube
C: Dry filter
4: Dismount starting device ECU
5: Dismount old compressor
6: Insert new compressor
7: Install starting device ECU
8: Solder
A. Suction and pressure tube
B. Capillary tube
C. Dry filter
Filling of new refrigerant
8: Drain refrigeration system by vacuum suction
9: Fill 50g of R600a refrigerant on the system