* 3lt in A1; 2,5lt in A2.
** 0,5lt in A1; 1lt in A2.
*** In service test the unsuccessful heating failure routine works with reduced time of
recognize (first measure at 2’20”, second measure t 4’20”)
If during the service test, the door is opened, Start/Stop led blinks (for models w/ display “SP” is
shown).
If during the service test, the Start/Stop button is pressed, the program corresponding
on the program leds(for models w/o display) or display(for models w/ display) position
starts.
To reset the service test, press On/Off button or plug out and then plug in.
Also at the end of the test, if an error does not occur, any error code is not visualized.
Machine will be standby position.
Note: If user did not set water hardness level before service test, “SE” is shown at the
beginning and end of service test.
SERVICE FAILURE CODES
For models w/o display;
Name
S_P
Wash
Dry
End
display Notes
Overflow/Leakage
-
Blink
-
Blink
F0/F1 In the normal work only leakage is
visualized.
Drain time out
Blink
-
-
Blink
F2
Presence Flow
meter impulses
-
-
-
Blink
F3
Absence Flow
meter imp.
-
Blink
-
-
F4
In the normal work is not visualized.
Empty Level
Blink
-
-
-
F5
Re-Fill time out
Blink
-
-
-
F5
NTC ca/cc
Blink
Blink
-
-
F6
Overheating
Blink
-
Blink
-
F7
Unsuccessful
heating
-
Blink
Blink
-
F8
In the normal work is visualized at the end of
prg
Parameter set salt
incorrect
Blink
Blink
-
Blink
SE
In the normal work this failure is not
visualized.
CK Parameters
Blink
Blink
Blink
Blink
FE
HIGH VOLTAGE
Blink
Blink
Blink
-
HI
LOW VOLTAGE
-
Blink
Blink
Blink
LO
13
Summary of Contents for A Series
Page 1: ...A SERIES 1 ...
Page 60: ......
Page 65: ...VESTEL DISWASHER MACH CUSTOMER SUPPORT UPPER HYDROLIC GROUP WHITE GOODS ...