-11-
fig.e
fig.f
fig.g
:for "CF-PCV"
:for "CF-R"
■
change to "CF-PCV"
①
Remove the fader knobs. (see fig-a)
②
Remove the bottom cover. (see fig-b)
③
Remove the 2 screws which fix the crossfader unit, and
remove the fader unit from position in mixer. (see fig-c)
④
Carefully remove the multi-cable connector from the
fader unit. (see fig-d)
⑤
Remove the screws which fix the crossfader volume.
(see fig-e)
⑥
Remove the knob and the panel of new a new fader unit
"CF-PCV". (refer to fig-f)
⑦
Secure the CF-PCV without panel and knob using
original screws. Only 2 screws are used to secure the
CF-PCV. (see fig-g)
⑧
Attach multi-cable connector to new fader unit.
⑨
Position the fader unit carefully and secure with screws.
■
change to "CF-R"
①
Remove the objective crossfader in the same procedure
as above
①〜⑤
.
②
Remove the knob and the panel of a new fader unit "CF-
R". (see fig-f)
③
Secure the CF-R without panel and knob using original
screws. Only 2 screws are used to secure the CF-R.
(see fig-g)
④
Attach multi-cable connector to new fader unit.
⑤
Position the fader unit carefully and secure with screws.
HOW TO CHANGE THE CROSS FADER UNIT
Note
Set switch to "PCV" position.