background image

Contents

Introduction / General

page 20

Manual mode

page 21

Automatic mode

page 22

Programming the up time

page 23

Programming the down time

page 24

Erase of the programmed up and down times

page 25

Notes for professional electricians

page 26 – 27

Installation instructions and measure diagrams

page 28

Technical data 

page 29

Wiring diagram

page 30

Wiring diagram

Inside back cover

Indication-/operating elements

Inside back cover

Warranty terms

Back cover

- 19 -

G

Introduction General

The delivery extent of the 

Vestamatic

VestaLogo 500

roller shutter

control includes the following items:
1. supporting frame
2. basic housing
3. cover cap
4. combination frame one-fold – Jung “CD 500”, alpine-white

In case of power failure the times which are programmed will be

saved for three hours. The commands that should be running during

this time will not be executed.
Please note that the roller shutter control must be mains-connected for

about 14 hours, to have the memory functions work properly.

- 20 -

G

Summary of Contents for VestaLogo 500

Page 1: ...lle der Besch di gung darf das Ger t keinesfalls in Betrieb genommen werden Sollte ein Trans portschaden vorliegen so ist unverz glich der Lieferant zu informieren Beachten Sie dass die Rolladensteuer...

Page 2: ...ichtig Wahlschalter auf A stellen Zur gew nschten Tageszeit Ab Taste f r 8 Sekunden dr cken bis Blinken der LED in Leuchten bergeht Wichtig Wahlschalter auf A stellen Auf und Ab Taste gleichzeitig f r...

Page 3: ...ige Bedienungselemente Seite 16 Garantiebedingungen Ausklapper letzte Umschlagseite Einleitung Allgemeines Der Lieferumfang der Rolladensteuerung Vestamatic VestaLogo 500 besteht aus 1 Tragrahmen 2 Gr...

Page 4: ...die Automatik Steuerung zu aktivieren Wahlschalter auf A stellen ganz nach links schieben bis zum Klick Die Automatik Steuerung ist somit aktiviert Der Rolladen f hrt nun zu den jeweilig programmierte...

Page 5: ...antes Leuchten der LED wechselt ist die Auffahrzeit programmiert und der Rolladen f hrt von nun an t glich um diese Uhrzeit auf Eine evtl zuvor programmierte Auffahrzeit ist hiermit gel scht es gilt a...

Page 6: ...khaube der Rolladensteuerung Vestamatic VestaLogo 500 durch leichtes Ziehen entfernen 3 Tragrahmen vom Geh use trennen 4 Tragrahmenanschlussklemme gem Anschlussplan siehe Seite 14 anschlie en Bitte be...

Page 7: ...Kombinationsrahmen 2 fach Artikel Nr 01400202 Kombinationsrahmen 3 fach Artikel Nr 01400203 Kombinationsrahmen 4 fach Artikel Nr 01400204 Kombinationsrahmen 5 fach Artikel Nr 01400205 Zur Aufputzmonta...

Page 8: ...eit 120 Sekunden Softwareklasse A Betriebstemperaturbereich 0 40 C Schutzart IP40 Verschmutzungsgrad 2 Technische nderungen vorbehalten p Das CE Zeichen ist ein Freiverkehrszeichen das sich aus schlie...

Page 9: ...ogrammiert leuchtet konstant eine Auffahrzeit ist programmiert Auf Taste Ab Taste rechte LED blinkt langsam der Antrieb f hrt ab blinkt schnell es wird eine Abfahrzeit programmiert leuchtet konstant e...

Page 10: ...art up the control in case there is any damage If there is damage due to the shipping please notify the supplier immediately Please note that the roller shutter control requires an operating voltage o...

Page 11: ...operating elements Inside back cover Warranty terms Back cover 19 G Introduction General The delivery extent of the Vestamatic VestaLogo 500 roller shutter control includes the following items 1 suppo...

Page 12: ...ode Push the selection switch to A all the way to the right until you hear the click in order to activate the automatic mode The automatic mode is now activated and the roller shutter will move up and...

Page 13: ...t LED blinks quickly When the blinking changes into continuous lighting the up time has been programmed and the roller shutter will move up at this time every day Any up time programmed before has bee...

Page 14: ...ulling carefully 3 Separate the supporting frame from the housing 4 Connect the supporting frame terminal according to the wiring dia gram page 30 Please note the position of the combination frame Jun...

Page 15: ...two fold article no 01400202 Combination frame three fold article no 01400203 Combination frame four fold article no 01400204 Combination frame five fold article no 01400205 For surface type installat...

Page 16: ...ating temperature 0 C 32 F to 40 C 104 F IP class IP 40 Degree of contamination 2 All technical data is subject to change p The CE mark is a free market mark which exclusively refers to the authority...

Page 17: ...continuously a down time has been programmed reset button button behind cover cap selection switch automatic manual mode rechte LED blinkt langsam der Antrieb f hrt ab blinkt schnell es wird eine Abfa...

Page 18: ...Garantiezeit ein Es werden keine Ein und Ausbaukosten durch Vestamatic bernommen D Art Nr 83101011 M1 Warranty terms For new devices the Vestamatic GmbH issues a warranty period of 24 months starting...