2
Within 1.5 seconds, press the Function Button 3 times.
Refer to the operation manual of the Z-wave gateway or control panel to complete the learn-in process.
If the device has already been
included
(learnt) into another Z-wave Gateway/Control Panel, or if the device is
unable to be learnt into the current Z-wave Gateway/Control Panel, please exclude it first (see
Exclusion
)
before attempting to
include
it into the current Z-wave Gateway/Control Panel.
E
E
x
x
c
c
l
l
u
u
s
s
i
i
o
o
n
n
(
(
R
R
e
e
m
m
o
o
v
v
i
i
n
n
g
g
D
D
e
e
v
v
i
i
c
c
e
e
)
)
The device must be removed from existing Z-wave network before being included into another. There are two
methods available to exclude a device.
Exclusion Mode
Put the Z-wave gateway or control panel into
Exclusion mode
(please refer to the Z-wave gateway or control
panel manual).
Within 1.5 seconds, press the Function Button 3 times and the device will be removed from the Z-wave
network.
Factory Reset
(Only use factory reset when network Control Panel/Gateway is missing or inoperable).
Press and hold the Function Button of the device for 10 seconds to factory reset.
<
<
N
N
O
O
T
T
E
E
>
>
Factory resetting the device will restore it to factory default settings (excluded from the Z-wave network).
The Z-wave gateway or control panel will still keep its Z-wave settings. Please refer to the gateway or
control panel manual on how to remove the device’s Z-wave settings.
Factory resetting the device will also clear all accumulated power data.
Range Test
To test whether the device is able to communicate with the Z-Wave Gateway or Control Panel:
Put the Gateway / Panel into range test mode (Walk Test).
Press the Function Button on the device.
The Gateway / Panel should display if the device is within the operation range (please refer to the operation
manual of the Gateway / Panel).
O
O
p
p
e
e
r
r
a
a
t
t
i
i
o
o
n
n
After being included into a Z-wave gateway or control panel, plug a home appliance into the Power Switch. This
home appliance’s power and energy usage data will be transferred to the Gateway / Control Panel.
Pressing the switch button on the Power Switch can also toggle on/off the Power Switch.
Remotely turn on/off the electric appliance through the Control Panel (please refer the manual of your Control
Panel).
If the power output is below 1kW, PSM-DIN3 will transmit a signal to Z-wave gateway/panel when the power
deviates by +/- 2W to update PSM-DIN3’s power information.
If the power output is above 1kW, PSM-DIN3 will transmit a signal to Z-wave gateway/panel when the power
deviates by +/- 5W to update PSM-DIN3’s power information.
PSM-DIN3 transmits a signal with power data to Z-wave gateway/panel every 10 minutes starting from the last
time a signal is transmitted.
The Power Switch transmits a signal with power data to Z-wave gateway/panel whenever power usage
increases by 0.1kW/hr.
If power of the Power Switch is reconnected from a previous disconnection, the previous on/off status of Power
Switch will be resumed immediately.
When the power is below 20W, measurement error is more likely to occur.
P
P
o
o
w
w
e
e
r
r
S
S
p
p
e
e
c
c
i
i
f
f
i
i
c
c
a
a
t
t
i
i
o
o
n
n
For
110V:
the maximum operation load is 3300W and 30A. Warning: please do not exceed the maximum load.
For
230V:
the maximum operation load is 6900W and 30A. Warning: please do not exceed the maximum load.
O
O
v
v
e
e
r
r
h
h
e
e
a
a
t
t
P
P
r
r
o
o
t
t
e
e
c
c
t
t
i
i
o
o
n
n
When the Power Switch is overheating, it will turn off automatically. When the temperature returns to normal, it will
turn on automatically to resume normal operation.
Z-Wave Information
Device Type:
Generic Type Switch Binary
Role Type:
Always On Slave (AOS)