There are two methods for shutting down the subsystem. Choose one of the following procedures:
•
“Shutting down the enclosure – Telnet Connection” on page 522
•
“Shutting down the enclosure– Serial Connection” on page 524
s
huttiNg
dowN
the
eNClosure
– t
elNet
C
oNNeCtioN
This function shuts down the Vess R2000 subsystem on a Telnet connection. Additional action is required, as
described below.
Important
If you have a JBOD Expansion, always power off the RAID subsystem first.
Then power off the JBOD subsystems.
To shutdown the RAID subsystem:
1. From the Main Menu, highlight
Additional Info and Management
and press
Enter
.
2. Highlight
Shutdown or Restart
and press
Enter
.
3. Highlight
Option
and press the spacebar to display
Shutdown
.
4. Highlight
Submit
and press
Enter
.
A warning message appears.
5. Press Y to continue.
The screen goes blank.
6. Wait for no less than two minutes.
7. The subsystem will then turn off the system power one after another.
Summary of Contents for R2000 SERIES
Page 1: ...ProductManual ...
Page 2: ...Vess R2000 Series Product Manual Version 2 0 2014 PROMISE Technology Inc All Rights Reserved ...
Page 83: ...Vess R2600i with SAS JBOD expansion 56 Vess R2000 Series Product Manual Promise Technologies ...
Page 151: ...124 Vess R2000 Series Product Manual Promise Technologies Topology display ...
Page 302: ...275 Product Manual NAS Function and Management Redundancy with port configuration ...
Page 704: ... 2014 PROMISE Technology Inc All Rights Reserved ...