Circuit open or short circuit to negative:interruption of the circuit or null voltage between control unit
connector PIN 11 and 12.
Troubleshooting
Short circuit to positive:
- Disconnect the control unit connector and the sensor connector.
- Verify that there is no short to battery positive on sensor connector PIN 3 (corresponding to control
unit connector PIN 11); in the presence of short circuit, restore the cable harness.
- Verify that there is no short to battery positive on sensor connector PIN 4 (corresponding to control
unit connector PIN 12); in the presence of short circuit, restore the cable harness.
Open circuit:
- Disconnect the control unit connector and the sensor connector.
- Check the continuity of the cable harness between the sensor connector and control unit connector:
Control unit PIN 11 - sensor PIN 3 and control unit PIN 12 - sensor PIN 4. If necessary, restore the
cable harness.
- If the cable harness is intact and the error persists, proceed with the following checks.
Short circuit to negative:
- Disconnect the sensor connector and the control unit connector.
- Check the sensor connector PIN 3 from ground insulation. If there is no insulation, restore the cable
harness.
- Check the sensor connector PIN 4 from ground insulation. If there is no insulation, restore the cable
harness.
- If PIN 3 and PIN 4 are insulated from the ground and the error persists, this means that there is a
probable fault in the control unit.
P0135 Lambda probe heating
- shorted to positive / shorted to negative / open circuit.
Error cause
Shorted to positive: excessive voltage at PIN 31 of the control unit connector.
Shorted to negative: lack of insulation from ground on the sensor connector PIN 1.
Open circuit: circuit interruption.
Troubleshooting
Shorted to positive:
- Disconnect the control unit connector and the sensor connector.
- Verify that there is no short to battery positive on sensor connector PIN 2 (corresponding to control
unit connector PIN 31); if there is a short, restore the cabling.
Open circuit:
- Disconnect the control unit connector and the sensor connector.
- Check continuity of the cabling between the sensor connector and the control unit connector: control
unit PIN 31 - sensor PIN 2. Restore the cabling if necessary.
Vespa LX - S 125 3V ie 150 3V ie (2012)
Electrical system
ELE SYS - 105
Summary of Contents for S 2012
Page 1: ...SERVICE STATION MANUAL 677662 EN Vespa LX S 125 3V ie 150 3V ie 2012 ...
Page 4: ......
Page 6: ...INDEX OF TOPICS CHARACTERISTICS CHAR ...
Page 27: ...INDEX OF TOPICS TOOLING TOOL ...
Page 37: ...INDEX OF TOPICS MAINTENANCE MAIN ...
Page 48: ...INDEX OF TOPICS TROUBLESHOOTING TROUBL ...
Page 52: ...Troubleshooting Vespa LX S 125 3V ie 150 3V ie 2012 TROUBL 52 ...
Page 53: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS ...
Page 54: ... LX VERSION S VERSION Electrical system Vespa LX S 125 3V ie 150 3V ie 2012 ELE SYS 54 ...
Page 69: ... S VERSION Vespa LX S 125 3V ie 150 3V ie 2012 Electrical system ELE SYS 69 ...
Page 72: ... S VERSION Electrical system Vespa LX S 125 3V ie 150 3V ie 2012 ELE SYS 72 ...
Page 75: ... S VERSION Vespa LX S 125 3V ie 150 3V ie 2012 Electrical system ELE SYS 75 ...
Page 109: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE ...
Page 114: ...INDEX OF TOPICS ENGINE ENG ...
Page 174: ...INDEX OF TOPICS INJECTION INJEC ...
Page 206: ...INDEX OF TOPICS SUSPENSIONS SUSP ...
Page 226: ...Suspensions Vespa LX S 125 3V ie 150 3V ie 2012 SUSP 226 ...
Page 227: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS ...
Page 236: ...INDEX OF TOPICS CHASSIS CHAS ...
Page 246: ...INDEX OF TOPICS PRE DELIVERY PRE DE ...
Page 251: ...Tyres 11 V Vehicle 8 110 ...