Short Case Axial Fans

Installation, Operation & Maintenance Manual

VES  Andover  Ltd.  Eagle  Close,  Chandlers  Ford  Ind.  Est,  Eastleigh,  Hampshire,  SO53  4NF

Tel:  08448  15  60  60      Fax:  02380  26  12  04      E-mail:  [email protected]      Web:  www.ves.co.uk

Maintenance

7

In  general,  this  series  of  units  require  little  maintenance.  In  the  unlikely  event  of
component  failure,  spares  are  available  from  stock  at  VES  Andover  Ltd.

When  enquiring  about  or  ordering  spares  contact  VES  Spares  Department,  quoting  the
sales  order  (SO)  number  and  unit  type  found  on  the  unit  nameplate.

Tel: 08448 15 60 60 - Fax: 02380 26 12 04

Spares & repairs

Before  attempting  to  carry  out  any  work  on  our  units,  all  accompanying  documentation
including  warning  labels  on  the  unit  must  be  referenced.
Should  it  be  necessary  to  remove  any  component  ensure  that  these  are  secured  into
position  once  reinstalled.  It  is  critical  that  after  any  maintenance  work  has  been  conducted
that  all  components  removed/replaced  be  refitted  correctly  by  a  competent  engineer.

Important

Before  attempting  to  carry  out  any  maintenance  work,  investigative  or  repair  work  on  our
units,  the  unit  MUST  BE  COMPLETELY  ISOLATED

 

from  its  electrical  supply.  Ensure  a  minimum

of  two  minutes  after  electrical  disconnection  before  removing  access  panels.

Warning

PLEASE ENSURE THIS DOCUMENT IS PASSED ON TO THE END USER

We reserve the right to alter the specification without notice © VES Andover Ltd. 2012. No part of this
publication may be photocopied or otherwise reproduced without the prior permission in writing of
VES Andover Ltd.

Care  should  be  taken  whilst  cleaning  the  unit  in  the  event  that  air  movement  should  cause
the  fan  to  freewheel.

Caution

Check  inside  the  unit  for  an  accumulation  of  dust,  grease  etc.  If  the  fan  impellor  is  heavily
soiled,  clean  out  carefully,  ensuring  the  unit  is  properly  isolated.  Failure  to  do  this
periodically  could  lead  to  aloss  of  performance  or  the  fan  to  become  out  of  balance,
leading  to  bearing/fan  failure.

Annual Checks

At  the  end  of  their  useful  life  the  packaging  and  product  should  be  disposed  of  via  a
suitable  recycling  centre.  Do  not  dispose  of  with  normal  household  waste.  Do  not  burn.

WEEE Directive

Commissioning

6

Before  operation,  the  following  checks  should  be  carried  out:
•

Installation  and  electrical  connection  have  been  carried  out  as  per  the  instructions  in
this  document  and  associated  documents.

•

Safety  equipment  is  in  place,  (terminal  box  cover  overload  protection,  Isolators  installed)

•

All  leftover  materials  and  other  foreign  materials  have  been  removed  from  the  fan  cavity
before  start  up.

•

Earth  has  been  connected

•

Temperature  monitor/motor  protection  has  been  connected  if  required.

•

Cable  gland  is  properly  sealed.

•

Check  for  correct  fan  rotation  direction  of  three  phase  fans  as  stated  on  the  fan  blade.  If
the  rotation  is  incorrect,  interchange  any  two  phases  of  the  incoming  supply  at  the
terminal  block.

If  these  checks  are  carried  out,  and  risk  is  assessed  as  being  low,  the  unit  can  be  switched  on.

Summary of Contents for Short Case Axial series

Page 1: ...iting www ves co uk and following the Information centre O M s link This manual must be read in full before installation operation and maintenance of the units Important The following symbols used wit...

Page 2: ...uoting sales order SO number and the unit type as found on the unit nameplate After this period we will be unable to accept any claim for damaged or missing goods Receipt of Goods Handling 3 AX350 4 1...

Page 3: ...llation guidelines should be followed Do not install Short Case Axial fans without adequate support Mounting surface must be even Axial fans must be supported independently from ductwork Ensure that t...

Page 4: ...30 9 8 AX450 4 1 160 175 6 515 451 9 5 487 12 x 30 15 2 AX500 4 1 166 176 6 567 503 9 5 541 12 x 30 15 7 AX560 4 3 210 228 7 635 539 11 5 605 16 x 22 5 20 1 AX630 4 3 220 226 7 707 634 11 5 674 16 x 2...

Page 5: ...the fan terminal box lid and in figures 6 and 7 Make the connection in the fan terminal box using the gland provided When used in conjunction with a speed controller make sure that the correct speed c...

Page 6: ...E U1 Brown U2 Blue Z1 Black Z2 Orange TB White L2 L1 V1 U2 U1 W2 TB TB W1 PE V2 L3 L3 V2 PE W1 TB TB W2 U1 U2 V1 L2 U1 Brown V1 Blue W1 Black U2 Red V2 Grey W2 Orange TB White Delta High speed connec...

Page 7: ...ion without notice VES Andover Ltd 2012 No part of this publication may be photocopied or otherwise reproduced without the prior permission in writing of VES Andover Ltd Care should be taken whilst cl...

Page 8: ...0 1 2 3 4 5 1 2 3 4 6 78 5 2 5 2 9 5 1 2 7 9 1 3 4 9 5 1 3 2 7687 5 3 5 0 476 2 7 6 9 A B A 7...