![Vertiqual Engineering LISKO Instruction Manual Download Page 3](http://html1.mh-extra.com/html/vertiqual-engineering/lisko/lisko_instruction-manual_1007797003.webp)
Edition: 08.04.2019
VISUAL CHECKS!
Warning: Before each use, the integrity and compatibility of the equipment must be checked! If damage is identified, the equipment must be immediately with-
drawn from use! If there is any doubt regarding the condition of the equipment DO NOT USE IT, instead send it to the manufacturer or to an authorized representative of
the manufacturer for a professional evaluation.
The equipment must be immediately removed from service if:
1. The marking/label is missing or is unreadable.
2. DAMAGE has been identified (incisions, cuts, tearing, worn seams, discoloration, hardened or thinned areas, burns, melted areas, rust, plastic defor-
mations) if any other abnormalities of the parts or structure have been found or if the product had suffered any changes compared to its original condition!
Below some examples of damage are illustrated:
3. Contact with paints or unknown chemicals had occurred (irreversible contaminations).
INSTALLATION WAYS OF THE ANCHOR SLINGS
BL = Breaking Load [kN]
BL
approx. 200% BL
approx. 400% BL
approx. 200% BL
approx. 50% BL
!!! DANGER !!!
approx. 35% BL
!!! DANGER !!!
WARNING!
WARNING!
WARNING!
WARNING! Only certified connectors (EN 362) will be
used for rigging the anchor slings / connecting lanyards.
Carefully read the instructions of the connectors you
intend to use and of the other components of the
system!
It is STRICTLY FORBIDDEN to use these anchor
slings / connecting lanyards for lifting or handling
materials! Personal Protective Equipment against
Falls should never be used as lifting equipment!
When building complex, multi-anchor rigging systems
using triangle layouts, keep the angle between the slings
(α)
as acute as possible! Wide angles multiply load
(Rf)
transmitted to each anchor! We recommend
to always use slings of appropriate length, to keep the
angle below 60° !
For
α
≤ 60° → R
f
≈ 60% F OK
For
α
≥ 90° → R
f
≈ 70% F OK
For
α
≥ 120°→ R
f
≈ 100% F WARNING!!!
For
α
≥ 150°→ R
f
≈ 200% F DANGER!!!