Vertiqual Engineering LISKO Instruction Manual Download Page 1

Edition: 08.04.2019 

 

Instruction manual for anchor slings / connecting lanyards, type 

LISKO, ANILLO, VANGUARD, FLEX and HARDY, certified according to EN 354, EN 566 and EN 795 

VANGUARD   VANGUARD X 

     LISKO   LISKO X 

ANILLO 

ANILLO X 

FLEX 

HARDY 

HARDY-R 

         

 

 

            

 

 

         

 

 

 

 

16mm, Dyneema

®

 

BL > 25 kN 

26mm, PES

 

BL > 30 kN 

35mm, PES

 

BL > 40 kN 

45mm, PES

 

BL > 25 kN 

Ø 8mm, steel wire rope 

 BL > 35 kN 

                                                                                                                                                                                             *BL = Breaking Load [kN]    

 
   Thank you for choosing VERTIQUAL®! You have purchased a high quality product that will reliably protect you and will be your companion for a long time when work-
ing at heights and depths. 

 
This manual must be read and understood before using the product! This product will be used with other equipment (components) thus forming a system for working at 
heights. Please refer to the instruction manual of each component in your system for compatibility and correct use! Following these instructions accordingly is essential 
for your safety. Failure to do so can result in serious or even fatal accidents! Keep these instructions together with the product, accessible to all users, so they can consult 
them whenever is needed! 
 

WARNING! 
These instructions are a basic comprehensive guide to the safe use of the purchased equipment. They contain general information about the product, intended to help 
the user, but cannot cover all the situations that may occur in the daily activities and cannot in any case replace the specialized training courses for safety at heights. This 
PPE against falls from heights can only be used by well-trained users, who are familiar with the relevant legislation and who have successfully completed a special safety 
training course for working at heights. 

 

WARNING!

  

For works with risk of falling from heights or in depths, a risk assessment must be carried out in advance in accordance with current regulations and legal provisions (EN 
standards or specific national rules) that will provide adequate measures for safety and rescue!

 

 

WARNING!

 

Instructions for use are updated when technical or legislative changes occur. The latest version of the instructions overwrites previous versions and is the only valid 
version. Please make sure you follow the instructions of the most recent version.  
You can download the most recent instructions from our website 

www.vertiqualsafety.com

  by accessing the section of each product.  

For help or additional questions, please contact us at 

[email protected]

  or Tel. (+40) 0365/882143. 

 
FIELD OF USE 
Anchor slings are used to create temporary anchor points, in situations where the size and geometry of an anchor structure is not suitable for attaching a carabiner direct-
ly to it. These can be used also to create a secure access path when climbing structures and different types of ladders. Another application of the anchor slings is the 
creation of multiple anchor points when building complex systems for working at heights and rescue. Along with other tested and certified components, the anchor slings 
are used to create fall arrest systems. The purpose of this systems is to stop the free fall of the user, absorbing most of the shock and distributing the remaining force 
evenly, while holding the users body in a proper position until he or she is rescued. The product must be used exclusively as a PPEaF (Personal Protective Equipment 
against Fall), in usual environments with temperatures between -30

 and +50

,

 

without potentially explosive atmospheres, far away from flames, sparks or hot metal 

splash. Avoid contact with sharp edges, electricity, chemicals, corrosive solutions and substances, excessive heat, oils, paints or any other contaminants. The structures 
used for anchoring have to meet the requirements of EN 795-2012, must have NO sharp edges and must be capable to withstand minimum 12 kN. The anchor point must 
be located as high as possible above the user and as close as possible to the vertical axis of the user’s position, thus reducing the fall distance and prevent pendulum 
accidents. The minimum free space below the user (fall clearance) must be ensured to prevent hitting the ground or any obstacles while the fall is arrested.     
 
These products are approved for single person use!                              

EN 

Summary of Contents for LISKO

Page 1: ...when technical or legislative changes occur The latest version of the instructions overwrites previous versions and is the only valid version Please make sure you follow the instructions of the most recent version You can download the most recent instructions from our website www vertiqualsafety com by accessing the section of each product For help or additional questions please contact us at offi...

Page 2: ... the sling The next component of the fall arrest system which will attach to the anchor sling can be Shock absorbing lanyard EN 354 and EN 355 Guided type fall arrester including a flexible anchor line EN353 2 Retractable type fall arresters EN 360 Semi static and Dynamic ropes of various systems for working at heights The anchor slings connecting lanyards shall be installed according to these ins...

Page 3: ...e illustrated 3 Contact with paints or unknown chemicals had occurred irreversible contaminations INSTALLATION WAYS OF THE ANCHOR SLINGS BL Breaking Load kN BL approx 200 BL approx 400 BL approx 200 BL approx 50 BL DANGER approx 35 BL DANGER WARNING WARNING WARNING WARNING Only certified connectors EN 362 will be used for rigging the anchor slings connecting lanyards Carefully read the instruction...

Page 4: ...n the work ing conditions and compulsory after every incident it has been involved in Inspections can be carried out only by the manufacturer or by an authorized inspections center If the periodic inspections were not performed at least once every 12 months were carried out by unqualified persons or without strictly respecting the man ufacturer s instructions the warranty is lost and the manufactu...

Reviews: