Discrete Controller Interface for non-TAC Systems
LD-16 Door Operator - Modernization
76
© Vertical Express
Discrete Controller Interface
(continued)
I/O Wiring Diagram
X5
N
120VAC, 6 AMPS
230VAC (not used)
PE
X2
+
(Optional)
X16
IPD
GND
Reference Switch
WPT
X40
X8
X60
X12
+24V
NO
O1
NC
NO
O2
NC
NO
O3
NC
NO
O4
NC
COM
I1
I2
I3
I4
I5
X1
Common
X15
GND
+24V
+
-
Transmitter
Receiver
Reopen
Position
Use relay
for low
contact
current
=
M
Encoder
Temperature Sensor
Transformer
Line In
T
X6
X9
PSM
X4
X10
X19
PMSM
Test Drive Buttons
Expansion Connector (not used)
1 2 3
LB+ Protection Device Supply
REV Input Protection Device
LB- Protection Device Supply
LB+ Protection Device Supply
L (junction terminal for LSE)
LB- Protection Device Supply
Note: Do not
connect any
supply
voltage to
the inputs
Open (Input 1)
Close (Input 2)
Nudging (Input 3)
Inspection (Input 4)
High Speed (Input 5)
Open End
Close End
Signals to lift control
Signals to lift control
Normally Open (Output 1)
Common (Output 1)
Normally Closed (Output 1)
Normally Open (Output 2)
Common (Output 2)
Normally Closed (Output 2)
Normally Open (Output 3)
Common (Output 3)
Normally Closed (Output 3)
Normally Open (Output 4)
Common (Output 4)
Normally Closed (Output 4)
Note: All of these inputs & outputs are galvanic insulated.
(Not used)