INSTALLATION
Vertical Express Product Manual
1-11
88600 v.1.0
Installation Section
Temporary Operation
Electronic Starter Setup
(continued)
6. Press
once and
OVERLOAD AMPS
displays.
a. If the value is correct, skip to Step 8.
b. If the value is not correct, continue to Step 7.
7. Press
once to access the value.
a. Press
or
to adjust the value of the flashing digit.
b. Press
to move to the next digit.
8. Press
to exit to the
PARAMETERS
Menu.
A prompt to
ACCEPT
or
REJECT
the change appears. Press
to accept, or
to
reject and correct the parameter.
Mechanical Starter Set Up with ESP200 Overloads
Overload relay current settings are preset by Manufacturing. The following initial
adjustment can also be used during temporary operation for jobs that trip overloads,
but the actual overload current will be set during final adjustment.
1. Use Table 1 below or Table 2 on page 1 - 12 to determine the overload relay cur-
rent setting based on the motor horsepower and voltage or nameplate amps.
2. Set the full load amps adjustment dial to the overload current setting from
Step 1. See Figure 10.
Figure 10 - ESP200 Overload Adjustment
Table 1 - Overload Specifications For Single Phase Motors
Full Load Amps
Adjustment Dial
Motor
HP
Motor Voltage
(50 or 60 Hz)
NEC Motor NP
Rated Amps
Wiring
Configuration
Overload
Current Setting
7.5
200V/208V
46
Special,
See Wiring Diagrams
50
230
40
43
10
200V/208V
58
62
230
50
54
Summary of Contents for ICON 32
Page 1: ...Controller...
Page 3: ...INSTALLATION SECTION...
Page 4: ...INSTALLATION SECTION...
Page 39: ...ADJUSTMENT SECTION...
Page 40: ...ADJUSTMENT SECTION...
Page 83: ...DIAGNOSTICS SECTION...
Page 84: ...DIAGNOSTICS SECTION...
Page 131: ...TROUBLESHOOTING SECTION...
Page 132: ...TROUBLESHOOTING SECTION...
Page 165: ...SERVICE INFORMATION SECTION...
Page 166: ...SERVICE INFORMATION SECTION...
Page 205: ...REFERENCE SECTION SERVICE REFERENCE SECTION...
Page 206: ...REFERENCE SECTION...