VX-2100/-2200 (VHF) Service Manual
13
5. Squelch (SQL)
This parameter is to align the SQL (Squelch) Sensitivity. The “RX VCO Tune Voltage”, “PLL Reference Frequency” and
“RX Sensitivity (RX Tune)” must be done before this alignment is started.
There are several alignments as follows in the Squelch Sensitivity.
Noise SQL Tight <Wide> (TH NSQ W)
: The Alignment for the Noise SQL Tight level at Wide (5k/4k).
Noise SQL Threshold <Wide> (TH NSQ W)
: The Alignment for the Noise SQL Threshold level at Wide (5k/4k).
RSSI SQL Level 11 <Wide> (RSSI SQL W)
: The Alignment for the “level 11“ of the RSSI SQL level at Wide (5k/4k).
RSSI SQL Full Scale <Wide> (S Full Scale W)
: The Alignment for the RSSI Full Scale level at Wide (5k/4k).
Noise SQL Tight <Narrow> (TI NSQ N)
: The Alignment for the Noise SQL Tight level at Narrow (2.5k).
N
oise SQL Threshold < Narrow > (TH NSQ N)
: The Alignment for the Noise SQL Threshold level at Narrow (2.5k).
RSSI SQL Level 11 < Narrow > (RSSI SQL N)
: The Alignment for the “level 11“ of the RSSI SQL level at Narrow (2.5k).
RSSI SQL Full Scale < Narrow > (S Full Scale N)
: The Alignment for the RSSI Full Scale levle at Narrow (2.5k).
The procedure for all the alignment is as follows.
1. Press the “Start” button to start the alignment.
2. Set the signal generator according to the level indi-
cated, then press “OK”.
3. Press the “OK” button after finish the alignment, then
the data will be saved and the alignment is accom-
plished.
4. RX Sensitivity (RX Tune)
This parameter is to align the RX BPF (Band Pass Filter) for Rx sensitivity. It must be done both alignments of the “RX
VCO Tune Voltage” and “PLL Reference Frequency” before this alignment is going to start.
1. Press the “Start” button to start the alignment.
2. Set the Signal Generator according to the indication,
then press “OK”.
3. Repeat the procedure no.2 until the 3point alignment
is finished.
4. It will show the result of 3 points alignment and press
“OK” then the confirmation window will open.
5. Press “OK” to finish the RX Sensitivity alignment and
save the data.
Alignment
Summary of Contents for VX-2100 series
Page 7: ...7 Block Diagram VX 2100 2200 VHF Service Manual...
Page 20: ...20 VX 2100 2200 VHF Service Manual MAIN Unit 25 W Lot 5 8 50W Lot 5 8 Circuit Diagram...
Page 23: ...23 VX 2100 2200 VHF Service Manual Circuit Diagram MAIN Unit 25 W Lot 9 17 50W Lot 9 17...
Page 26: ...26 VX 2100 2200 VHF Service Manual MAIN Unit 25 W Lot 18 20 50W Lot 18 20 Circuit Diagram...
Page 29: ...29 VX 2100 2200 VHF Service Manual MAIN Unit 25 W Lot 21 96 50W Lot 21 32 Circuit Diagram...
Page 35: ...35 VX 2100 2200 VHF Service Manual MAIN 2 Unit 50 W Lot 33 96 Circuit Diagram...