Vertex™ Rx-C 6D Calcium Reactor / Instruction Manual
© Vertex Aquaristik ™GmbH, Deutschland 2014
P
a
ge
2
Always think safety first! If you are unsure as how to operate this product; consult with a professional
or contact us directly.
Installation:
1-
Remove your Calcium Reactor and its components from the box and inspect for any possible defects. If
there are any concerns please contact your dealer within 48 hours of receiving your reactor, refrain from
installing the unit, keep all original packaging as well as proof of purchase.
Any damages to the unit during transport are not covered under warranty and must be claimed with
the forwarder at the time of receiving the product.
2-
After proper inspection, clean the unit with a damp cloth using RO water. This ensures removal of any
oils and/ or chemicals used during the manufacturing process. Each unit has been individually Leak-tested
both through high pressure Air and Water injection. Possible water marks or minimal amount of water
might be present in the reactor.
Tip: Although the unit has been tested for possible leaks and/or any other defects; it is recommended
to assemble the unit and run with water and no media for a few hours. Please follow this guide
without using any media. Once you are satisfied that your reactor is devoid of any defects you can
simply fill it with desired media(s) and put in operation.
3-
Rinse your Media with RO water.
Only use coarse media
.
4-
Remove Primary Chamber from the box.
Do not lift or hold the chamber by its upper manifold.
5-
Gently unscrew the Primary chamber’s lid. It is recommended to seek assistance for this task since the
lid might not be easily unscrewed. Hold the chambers Acrylic body and unscrew the lid pen. Place the lid
carefully on a soft surface to avoid breaking the internal parts.
Warning: Do not attempt to hold the chamber by its manifold or the connections on the lid. Doing so
WILL result in broken manifold or lid-connections. Such damages are not covered under warranty.
6-
Place one hand on the top of the chamber’s opening holding it down. Using the other hand gently remove
the upper perforated plate by pulling on the Titanium knob.
7-
Fill the Primary chamber with proper media. Do not pack media tightly. Do not fill the chamber full. Small
media particles can go through the bottom perforated plate. Do not be alarmed this will not affect
performance.
8-
Once filled, gently push down the upper perforate plate in place. Ensure that the O-Ring is properly
seated.