background image

VXR-9000 FM R

EPEATER

 O

PERATING

 M

ANUAL

F

RONT

 P

ANEL

 C

ONTROLS

 & C

ONNECTORS

POWER

 

(

O/I

) Switch

This is the main power switch for the repeater.

 

Power Indicator (

MAIN

)

This LED glows green when the main power source
is used.

 Power Indicator (

BACKUP

)

This LED glows red when the backup power source
is used.

 

MIC

 Jack

Connect the microphone plug to this jack. This jack
is also used for writing and reading channel fre-
quency or other configurations via the USB Port of
the PC on which the clone editor (

CE60

) is running.

 Programmable Function (

PF

) Key

Six pushbuttons on the front panel are program-
mable function (

PF

) keys, each with an orange indi-

cator inside. Each key can be programmed with two
functions, one for a “long” press and one for a “mo-
mentary” press. The 

PF

 key functions may be cus-

tomized, via programming by your VERTEX STAN-
DARD dealer, to meet your communications net-
work requirements. Note that some functions may
require the purchase of optional internal accesso-
ries. The possible PF key features and functions are
explained on the pages to follow.

 

VOL

 Knob

This control knob adjusts the output level of the front
speaker and external speaker jack on the back panel.

 

TX

 Indicator

This LED glows red when the repeater is transmit-
ting.

 Numeric Display

This display consists of two 7-segment LEDs, indi-
cating the channel number during normal operation.
If an abnormal condition arises, an error code will be
displayed:

2

D

ISPLAY

D

ESCRIPTION

01

 - 

32

Channel Number

PC

Clone Active

UL

PLL Unlock

HI

High temperature in PA Unit

SC

Scan Active

LC

Front Panel Keys are Locked

E1

PTT key is Disabled

E2

Cooling Fan is Disabled

E5

Low Voltage in Backup Battery

E7

PA Unit Abnormality

E3

E4

E6

E9

Contact your Dealer

 

 

BUSY

 Indicator

This LED glows green when the receiving channel
is busy.

 Speaker

The internal speaker is located here.

 

   

Summary of Contents for VXR-9000 Series

Page 1: ...VXR 9000 FM REPEATER OPERATING MANUAL VXR 9000 OPERATING MANUAL RACK MOUNT REPEATER Vertex Standard LMR Inc ...

Page 2: ...VXR 9000 FM REPEATER OPERATING MANUAL ...

Page 3: ... operation may result from improper setup programming or internal modifications SAFETY WARNING INFORMATION The antenna s used for this transmitter must be fixed mounted on outdoor permanent structures with a separation distance of at least 1 4 m from all persons during normal operation and must not exceed an antenna gain of 0 dBd This device must be restricted to work related operations in an Occu...

Page 4: ...RTEX STAN DARD dealer to meet your communications net work requirements Note that some functions may require the purchase of optional internal accesso ries The possible PF key features and functions are explained on the pages to follow VOL Knob This control knob adjusts the output level of the front speaker and external speaker jack on the back panel TX Indicator This LED glows red when the repeat...

Page 5: ...to CTCSS DCS Enc to turn the CTCSS DCS Encoder On or Off toggle CTCSS DCS DEC Press or Press and hold in for one second the PF key assigned to CTCSS DCS Dec to turn the CTCSS DCS Decoder On or Off toggle CW ID Press or Press and hold in for one second the PF key assigned to CW ID to turn the CW Identifier feature On or Off toggle When the CW ID feature is set to On your station s callsign will be ...

Page 6: ... or Press and hold in for one second the PF key assigned to Local PTT to enable On or disable Off operation using a PTT switch connected to the front panel s Microphone Jack MONITOR Press or Press and hold in for one second the PF key assigned to Monitor to cancel CTCSS and DCS squelch decoding so as to enable reception of signals present on the channel that do not contain a matching CTCSS tone or...

Page 7: ...witch to transmit the Test Tone Signal as programmed by your VERTEX STANDARD dealer TOT Press or press and hold in one second the PF key as signed to TOT to turn the Time Out Timer feature On or Off toggle When the TOT feature is set to On the repeater will return to the Receive mode automatically after a pre set time of continuous transmission determined via programming by your VERTEX STANDARD de...

Page 8: ...ng an tenna or the TX jack on the duplexer The output impedance requirement is 50 Ohms Main Power Source Connector The primary DC power source should be connected here The power requirements are 13 6 V DC at 12 Amps continuous duty External Speaker Jack This 3 5 mm 2 pin jack provides variable audio output for an external speaker The audio output impedance at this jack is 4 to 16 Ohms and the leve...

Page 9: ...s pin connecting the shield to GND Pin 5 TX ATT This output is intended for controlling an external co axial switching relay It is an open drain output which can sink approx 1 5Awhen active The delay time which is between the repeater cause to transmit mode and this port switches to ground can be programmed by your VERTEX STANDARD dealer Pin 6 DISC OUT ANALOG OUTPUT WIDE BAND 0 3 000 HZ Received s...

Page 10: ...GND Chassis ground for all logic levels and power supply return Pin 22 RXD LOW ANALOG OUTPUT FOR DATA COMMUNICATIONS 300 3 000 Hz This pin is an output for low speed receiving data sig nals with the data being extracted after the de empha sis and low pass filter stages Pin 23 RXD HIGH DIGITAL OUTPUT FOR DATA COMMUNICATIONS This pin is an output for high speed receiving data sig nals with the data ...

Page 11: ...0 Ω at the operating frequency When separate receive and transmit antennas are used high Q narrow band types may serve to minimize interaction NEVER TRANSMIT WITHOUT HAVING A TRANSMIT ANTENNA CONNECTED TO THE TX ANTENNA JACK OF THE REPEATER Equipment Location The VXR 9000 must be installed in a 19 inch Mounting Rack which will allow for free air flow around the heat sink on the rear apron at all t...

Page 12: ...er is operat ing from the Main Power Source a slight charging cur rent will maintain battery charge In the event of an un expected interruption of the Main Power Source the automatic power control circuit will automatically switch the repeater to the backup battery and operation will not be interrupted After prolonged operation from the battery Backup Power Source it should be disconnected from th...

Page 13: ...000075 1 Knob Cap RA0506900 6 Name Plate RA0508500 1 Operating Manual 1 Optional Accessories FIF 9 Inline Interface Box FVP 25 Encryption Unit FVP 35 Rolling Code Encryption Unit MD 12A8J Desktop Microphone FIF 10A USB Programming Interface FIF 12 USB Programming Interface CT 104A PC Programming Cabel for FIF 10A and FIF 12 ...

Page 14: ...communications prod ucts against defects in materials and workmanship under normal use and service for a given period of time from the date of purchase Limited Warranty Details North America customers USA and Canada http www vertexstandard com lmr warranty terms aspx Customers outside of North America contact the authorized dealer in your country ...

Page 15: ...VXR 9000 FM REPEATER OPERATING MANUAL Part 15 21 Changes or modifications to this device not expressly ap proved by Vertex Standard could void the user s authorization to operate this device ...

Page 16: ...REPEATER OPERATING MANUAL Copyright 2013 Vertex Standard LMR Inc All rights reserved No portion of this manual may be reproduced without the permission of Vertex Standard LMR Inc Printed in Japan E C 0 4 4 N 1 0 5 ...

Reviews: