Vertex Standard VX-6000L Alignment Manual Download Page 5

FCC ID: K66VX-6000L

Alignment

Vertex Standard Co., Ltd.

5

Transmitter Deviation

Microphone Audio Modulation Level

・・

 

  

Select band center frequency channel, and adjust the AF generator for 25 mV(-30 dBm)

output at 1 KHz to the microphone jack.

・・

Key the transmitter and adjust by control commands for maximum deviation from the

computer for 4.2 KHz ±0.1 KHz deviation as indicated on the deviation meter.

CTCSS Modulation Level

・・

  Select band center frequency channel, with 151.4 Hz CTCSS encode, and reduce the AF

generator injection to zero.

・・

  Key the transmitter and adjust by control commands for CTCSS deviation from the

computer for 0.7 KHz ±0.05 KHz deviation as indicated on the deviation meter.

DCS Modulation Level

・・

  Select band center frequency channel, with DCS 023 enabled, reduce the AF generator

injection to zero.

・・

  Key the transmitter and adjust by control commands for DCS deviation from the computer

for 0.7 KHz ±0.05 KHz deviation as indicated on the deviation meter.

Receiver

・・

  Set up the test equipment as shown for receiver alignment, and construct the audio test

adapter as described in the box below.

・・

  With the transceiver set to band center frequency channel, and the RF signal generator

tuned to the same frequency,

set the generator for ±3.0 KHz deviation with 1 KHz tone

modulation, and set the output level for 1 µV at the antenna jack.

・・

  Adjust by control commands for tune from the computer for optimum SINAD, reducing

signal generator output level as necessary for proper meter deflection.

・・

  After the previous step, final signal generator level should be less than 0.25 µV for 12dB

SINAD.

Squelch Threshold

・・

  Select band center frequency channel, and the RF signal generator turned to the same

frequency, set the generator for ±3.0 KHz deviation with 1 KHz tone modulation, and set
the output level for -8 dBµ at the antenna jack.
Adjust the squelch threshold level by control commands for squelch threshold from the
computer so that it just closes (BUSY LED turns off).

Summary of Contents for VX-6000L

Page 1: ...icians realign all circuits and make complete performance checks to ensure compliance with factory specifications after replacing any faulty components Those who do undertake any of the following alignments are cautioned to proceed at their own risk Problems caused by unauthorized attempts at realignment are not covered by the warranty policy Also Vertex Standard must reserve the right to change c...

Page 2: ...0 A 50 Ω Non reactive Dummy Load 200 W at 100 MHz Frequency Counter 0 1 ppm accuracy at 100 MHz AF Signal Generator DC Voltmeter high impedance RF Sampling Coupler attenuation pad AF Dummy Load 4 Ω 20 W Oscilloscope Spectrum Analyzer IBM PC compatible computer w Vertex CT 71 programming cable CT 29 CT 70 and CE 35 channel programming editor 50 Ω RF Signal Dummy load Generator RF Sampling Inline Wa...

Page 3: ... oscillator shields and circuit boards firmly affixed in place Also the test equipment must be thoroughly warmed up before beginning Before beginning connect the transceiver and PC using the CT 71 programming cable as described in the EEPROM Programming chapter and download the EEPROM data from the transceiver to the computer Store this data in a disk file so that it can be saved and retrieved lat...

Page 4: ... for 7 0 V on the voltmeter Next select to the low edge frequency channel and confirm about 1 8 V 1 5 V to 2 1 V on the voltmeter Key the transmitter and confirm about 1 8 V 1 5 V to 2 1 V on the voltmeter PLL Reference Frequency With the wattmeter dummy load and frequency counter connected to the antenna jack and select band center frequency channel key the transmitter and adjust TC1001 on the Ma...

Page 5: ...om the computer for 0 7 KHz 0 05 KHz deviation as indicated on the deviation meter Receiver Set up the test equipment as shown for receiver alignment and construct the audio test adapter as described in the box below With the transceiver set to band center frequency channel and the RF signal generator tuned to the same frequency set the generator for 3 0 KHz deviation with 1 KHz tone modulation an...

Reviews: