background image

FCC ID: K6630043X30

IC ID: 511B-30043X30

Alignment

Vertex Standard Co,. Ltd.

7

ˆ

  In 3 seconds, send the INDIVIDUAL CALL from the conformation transceiver.

ˆ

  Confirm that the test transceiver receives the INDIVIDUAL CALL from the

conformation transceiver and outputs the beep.
Press the 

CALL/SET

 key of the test transceiver and turn off the beep.

Simultaneously, confirm that “123456780” of conformation transceiver’s MMSI is
displayed in the LCD of the test transceiver.

ˆ

  Confirm that the conformation transceiver receives the response from the test

transceiver and outputs beep.
Press the 

CALL/SET

 key of the conformation transceiver and turn off the beep.

Simultaneously, confirm that “TEST” of test transceiver’s MMSI is displayed in the LCD
of the conformation transceiver.

Summary of Contents for GX2360S

Page 1: ...ake complete performance checks to ensure compliance with factory specifications after replacing any faulty components Those who do undertake any of the following alignments are cautioned to proceed at their own risk Problems caused by unauthorized attempts at realignment are not covered by the warranty policy Also Standard Horizon a division of VERTEX STANDARD must reserve the right to change cir...

Page 2: ...smission Correct alignment is not possible with an antenna After completing one step read the following step to determine whether the same test equipment will be required If not remove the test equipment except dummy load and wattmeter if connected before proceeding Correct alignment requires that the ambient temperature be the same as that of the transceiver and test equipment and that this tempe...

Page 3: ...ode every time you press PTT the following test tone can be outputted 1st transmission Synthetic tone of 1300 Hz and 2100 Hz 2nd transmission 1300 Hz 3rd transmission 2100 Hz 4th transmission No Modulation 5th transmission Return to 1st transmission C Scan the channels between WX10 and EXP04 in the SCAN mode Adjustment of PLL Frequency Adjust the frequency in the transmit mode and local frequency ...

Page 4: ...tent to take the lowest possible value at the stop band near 150 MHz and the highest possible value at the band near 156 MHz Each coil shall be adjusted at the range between the initial condition and right and left revolving Starting Test Mode Confirm that turn off the transceiver and short the TEST points Press the PWR VOL switch while press and holding the and keys Then appear on display ALIGNME...

Page 5: ...z 0 1 kHz then press CALL SEL key Confirmation of Transmit Power Adjust power at high and low in the transmit mode and confirm power in the specified bandwidth Use the H L key to set transceiver to high power and set the channel to CH16 With the PTT switch pressed confirm that RF power is between 24 W 0 5 W Use the H L key to set transceiver to low power With the PTT switch pressed confirm that RF...

Page 6: ...0 and output level of the SSG to 20 dBµV 3 0 kHz deviation with 1050 Hz tone modulation Set the output of the SSG to ON Confirm that the channel of transceiver stops at WX10 and the transceiver outputs the weather alert tone 1050 Hz Confirmation of receiver NMEA data Input NMEA format data output from GPS receiver to NMEA terminal A of transceiver and display it to the LCD of the transceiver NMEA ...

Page 7: ...LL SET key of the test transceiver and turn off the beep Simultaneously confirm that 123456780 of conformation transceiver s MMSI is displayed in the LCD of the test transceiver Confirm that the conformation transceiver receives the response from the test transceiver and outputs beep Press the CALL SET key of the conformation transceiver and turn off the beep Simultaneously confirm that TEST of te...

Reviews: