background image

FCC ID: K66GX1255S

Alignment

Vertex Standard Co,. Ltd.

6

Confirmation of Weather Alert Tone

Confirmation of Weather Alert Tone

Confirmation of Weather Alert Tone

Confirmation of Weather Alert Tone
In the weather channel mode, when transceiver receives the specific emergency tone
(1050 Hz), weather alert tone will be output (Weather Alert Operation). The Weather
Alert mode will be active when a NOAA weather channel is in memory and radio is in
memory scan or P-scan mode.

-- Confirmation --

!

 

Connect the standard signal generator (SSG) to the antenna jack.

!

 

Squelch position set to tight.

!

 

Press the 

SCAN

 key and start to Memory Scan mode.

!

 

Set the SSG to 163.275 MHz (WX10) and output level of the SSG to 20 dBµV, ±3.0
KHz deviation with 1050 Hz tone modulation.

!

 

Set the output of the SSG to ON.

!

 

Confirm that the channel of transceiver stops at WX10 and the transceiver
outputs the weather alert tone (1050 Hz).

Confirmation of receiver NMEA data

Confirmation of receiver NMEA data

Confirmation of receiver NMEA data

Confirmation of receiver NMEA data
Input NMEA format data output from GPS receiver to NMEA terminal A of
transceiver and display it to the LCD of the transceiver.
NMEA format data output from GPS receiver is applied to NMEA terminal of
transceiver’s option connector and LCD of transceiver will show data.

-- Confirmation --

!

 

Setup the test equipment as shown below.

!

 

Press and hold the 

H/L

 key, confirm that the position data is displayed on the LCD

of transceiver.

Confirmation of DSC Operation

Confirmation of DSC Operation

Confirmation of DSC Operation

Confirmation of DSC Operation
-- Confirmation --

!

 

Prepare the confirmation transceiver (GX1260S).

!

 

Input below data to the confirmation transceiver in advance.

-

 

Input “TEST” to NAME of INDIVIDUAL DIRECTORY

-

 

Input “123456789” to MMSI of INDIVIDUAL DIRECTORY

-

 

Input “123456780” to local MMSI

-

 

Channel 13 in U.S.A. mode

!

 

Setup the test transceiver as follows:

-

 

Channel 21 in U.S.A.

!

 

In 3 seconds, send the INDIVIDUAL CALL from the conformation transceiver.

!

 

Confirm that the test transceiver receives the INDIVIDUAL CALL from the

Summary of Contents for GX1255S

Page 1: ...replacing any faulty components Those who do undertake any of the following alignments are cautioned to proceed at their own risk Problems caused by unauthorized attempts at realignment are not covered by the warranty policy Also Standard Horizon a division of VERTEX STANDARD must reserve the right to change circuits and alignment procedures in the interest of improved performance without notifyin...

Page 2: ...t except dummy load and wattmeter if connected before proceeding Correct alignment requires that the ambient temperature be the same as that of the transceiver and test equipment and that this temperature be held constant between 20 C and 30 C 68 F and 86 F When the transceiver is brought into the shop from hot or cold air it should be allowed some time for thermal equalization with the environmen...

Page 3: ... of VCO Confirmation of VCO Confirmation Connect the DC voltmeter to the test point LOCK TP Use the UP DOWN key to set the channel to EXP04 EXP04 EXP04 EXP04 confirm that voltage on the test point is over 1 0 V in the receive and transmit mode Use the UP DOWN key to set the channel to EXP05 EXP05 EXP05 EXP05 confirm that voltage on the test point is below 5 0 V in the transmit mode Use the UP DOWN...

Page 4: ...uency in the transmit mode and local frequency in the receive mode Adjustment Setup the test equipment as shown below Set the channel to CH16 CH16 CH16 CH16 With the PTT switch pressed adjust TC1001 so that RF frequency is 156 80000 MHz 50 Hz Adjustment and Confirmation of Deviation Adjustment and Confirmation of Deviation Adjustment and Confirmation of Deviation Adjustment and Confirmation of Dev...

Page 5: ...n below Set the center frequency of t he spectrum analyzer to 159 00 MHz set SPAN to 20 00 MHz set RBW and VBW to 30 KHz and set SWP to 56 ms Adjust T1001 T1002 T1003 T1004 and T1005 until the wave form shown in below is obtained Note Note Note Note Adjust the output of the tracking generator so that RF AMP and spectrum analyzer will not saturate Figure shows the reference wave form The wave form ...

Page 6: ...ata Confirmation of receiver NMEA data Confirmation of receiver NMEA data Confirmation of receiver NMEA data Input NMEA format data output from GPS receiver to NMEA terminal A of transceiver and display it to the LCD of the transceiver NMEA format data output from GPS receiver is applied to NMEA terminal of transceiver s option connector and LCD of transceiver will show data Confirmation Setup the...

Page 7: ...at 123456780 of conformation transceiver s MMSI is displayed in the LCD of the test transceiver Confirm that the conformation transceiver receives the response from the test transceiver and outputs beep Press the CALL SET key of the conformation transceiver and turn off the beep Simultaneously confirm that TEST of test transceiver s MMSI is displayed in the LCD of the conformation transceiver ...