Alignmenmt
3
Main Reference Frequency Adjustment
Setup the test equipment as shown below.
Set the channel to CH16.
Use the [H/L] key to set the transceiver to “LOW” power.
With the PTT switch pressed, adjust TC1001 so that the Frequency Counter
reading is 156.800 MHz ±100 Hz.
Transmit Power Adjustment
Setup the test equipment as shown below.
Set the channel to CH16.
Use the [H/L] key to set the transceiver to “HI” power.
With the PTT switch pressed, adjust VR1001 so that RF output power is 24 W ±0.3
W.
Release the PTT switch, then set the transceiver to “LOW” power by the [H/L] key.
With the PTT switch pressed, adjust VR1002 so that RF output power is 0.8 W ±0.1
W.
Release the PTT switch.
TX Deviation Adjustment
Setup the test equipment as shown below.
Set the AF Signal Generator output to 200 mVrms at 1 kHz.
Set the channel to CH16.
With the PTT switch pressed, adjust VR1003 so that the maximum deviation is 4.2
kHz ±0.1 kHz.
Release the PTT switch.
Receiver Front-end Adjustment
Setup the test equipment as shown below.
Set the spectrum analyzer as shown below:
CENTER: 159.000 MHz
SPAN: 20.000 MHz
RBW, VBW: 30 kHz
SWP: 200 ms
Adjust L1009, L1010, L1019, L1024, and L1028 until the wave form shown in below
is obtained.