Upload the configuration data from the VX-450 to the Computer by the “Upload” param-
eter in the “Radio” menu tab.
r
Click the left mouse button on the large
[SETUP] button, then set each parameter on
the “SETUP” tab. Refer to the CE104 Help
files regarding the details of the function of
each parameter.
r
When finished changing the settings, down-
load the configuration data from the Com-
puter to the VX-450 by selecting the “Down-
load” parameter in the “Radio” menu tab.
r
Programming is now complete. Perform the
alignment of the Man Down sensor of the
DVS-9, if needed.
dVs-9 u
nit
a
djustment
(
u
sing
ce104
)
I
mportant
n
ote
: The DVS-9 is adjusted at the factory. Therefore, the DVS-9 does not need
adjustment normally. Adjust the DVS-9 when the operation is abnormal.
r
Place (not lay down) the VX-450 on a hori-
zontal surface.
r
Click the left mouse button on the large
[ALIGNMENT] button, then click the [START]
button to open the “Angle Initialize” window.
r
Click the left mouse button on the [OK] but-
ton to initiate the alignment.
r
When the alignment is successful, click the
left mouse button on the [OK] button to ter-
minate the alignment.
r
Alignment is now complete. Close the
CE104 Programming Software and turn off the VX-450 by
rotating the VOL/PWR knob fully counter-clockwise.
p
rOgramming
The CE104 and CE115 Programming Software are needed to program the DVS-9. Install
the CE104 and CE115 to your computer in advance.
t
ransceiVer
p
rOgramming
(
u
sing
ce115
)
r
Connect the VX-450 transceiver (with the DVS-9 installed) to your computer with the
FIF-10A USB Programming Interface and CT-106 Programming Cable or the CT-42A
Programming Cable.
r
Execute the CE115 Programming Software, then upload the configuration data from the
VX-450 to the Computer by selecting the “Upload” parameter in the “Radio” menu tab.
r
Click the left mouse button on the “Key Function” param-
eter in the “Common” menu tab to open the “Key Function”
window.
r
Assign the “Option SW 2” (for activating/disabling the “Man
Down” function), assign the “REC”, and “PLAY” functions
to the desired keys, then click the [OK] button to close the
“Key Function” window.
r
If you want to edit the “Emergency” parameter after the
“Man Down” function is activated, select
the “Emergency” parameter in the “Com-
mon” menu tab. Refer to the CE115 Help
files regarding the details of the function of
each parameter. When finished changing
the settings, click the [OK] button to close
the “Emergency” window.
r
Click the left mouse button on the “Option” param-
eter in the “Common” menu tab to open the “Option”
window. Confirm the “Option Unit” parameter is set
to “DVS-9”.
r
Set each parameter of the “REC Mode”, “Play Pri-
ority”, and “Power ON REC” to the desired function, then click the [OK] button to close
the “Option” window. Refer to the CE115 Help files regarding the details of the function
of each parameter.
r
When finished changing the settings, download the configuration data from the Com-
puter to the VX-450 by selecting the “Download” parameter in the “Radio” menu tab.
r
Close the CE115 Programming Software and turn off the VX-450.
dVs-9 u
nit
p
rOgramming
(
u
sing
ce104
)
r
Execute the CE104 Programming Software.
r
Rotate the VOL/PWR knob clockwise while pressing and holding the TOP SEL and PTT
keys to turn on the VX-450 in the “Sub Clone” mode.
In the VX-451, a series of beeps will be heard to indicate the radio is in the “Sub Clone”
mode.
In the VX-454/-459, the “SUBCLONE” notation will appear on the
display and a series of beeps will be heard to indicate the radio is in
the “Sub Clone” mode.
a
dVice
The reference direction of the DVS-9 sensor is the same direction of the setting sta-
tus of the VX-450 when you adjusted it.
For example, If you adjust the VX-450 in the status that lay it down, reference direc-
tion of the DVS-9 sensor becomes horizontal.
- 3 -
- 2 -