O
peratiOn
r
Rotate the VOL/PWR knob clockwise to turn the VX-450 on.
r
Press (or press and hold) the Programmable key which is programmed to the “Option
SW 2” function to activate the “Man Down” function. In the VX-454/-459, the “ ” icon
will appear on the display.
r
When the VX-450 (DVS-9) senses the “Man Down” action, such as an operator falls
down, the VX-450 (DVS-9) operates in accordance with the programming of the CE104.
¦
You may disable the alarm tone that is generated by the “Man Down” function by
pressing the PTT key. However, the “Man Down” function is still “on”.
¦
You may disable the “Siren” that is generated by the “Man Down” function, by press-
ing the Programmable key which is programmed to the “Option SW 2” function (Dis-
abling the “Man Down” function).
¦
The VX-450 (DVS-9) which is in the “Stun” status by the “Man Down” function can-
not revive by itself. Revive the VX-450 (DVS-9) by the CE115 Programming Soft-
ware (Execute the “Upload” and “Download” functions).
¦
To disable the “Emergency” function that was activated by the “Man Down” function,
turn off the VX-450 by rotating the VOL/PWR knob fully counter-clockwise.
r
The VX-450 (DVS-9) does not detect the “Man Down” action again when sensing a “Man
Down” action once. In this time, restart the “Man Down” function by pressing the Pro-
grammable key which is programmed to the “Option SW 2” function twice.
r
To disable the “Man Down” function. Press (or press and hold) the Programmable key
which is programmed to the “Option SW 2” function again. In the VX-454/-459, the “ ”
icon will disappear from the display.
r
Refer to the REC and PLAY section of the VX-450 series operating manual for the op-
eration of the Digital Voice Storage feature.
Man Down Alert with Digital Voice Storage Unit
DVS-9
Installation & Operation Manual
The
DVS-9
is a Man Down Alert / Digital Voice Storage Unit, which monitors a variety of
worker timed safety scenarios (Man Down Alert feature) and allows you to record and play
back incoming receiver audio (Digital Voice Storage feature).
i
nstallatiOn
p
rOcedure
r
Make sure that the transceiver is turned off. Remove the hard or soft case, if used.
r
Remove the Battery Pack from the transceiver.
r
The connector for the DVS-9 is located under the Metal Cover in the battery compart-
ment on the back of the transceiver. Remove the two screws affixing the Metal Cover,
then remove the Metal Cover from the transceiver.
r
Align the connector of the DVS-9 with the transceiver’s option board connector and gen-
tly press the DVS-9 into place.
r
Peel off the Protective Sheet from the supplied Cushion Sheet, then affix the Cushion
Sheet in the position on the DVS-9 which is shown in the illustration below.
r
Replace the Metal Cover and its’ two screws.
r
Installation is now complete.