9
VX-1400 Series Service Manual
TP4039
J4002
TP4058
T4011
T4017
T4015
T4014
T4013
T4012
T4018
L4072
Alignment
MAIN U
NIT
A
LIGNMENT
P
OINTS
MIC J
ACK
P
INOUT
CL_DATA
CL_SW
+ 5V
GND
MIC
PTT
GND
HOOK
and then set the output level to 0 dBµV at the 19.9
MHz.
Press the [
] / [
] button to select the "memory chan-
nel 017".
Adjust T4016 on the MAIN-Unit for maximum deflec-
tion on the AF millivoltmeter.