VersiVision FVR1103 Technical Manual Download Page 7

 

  www.versitron.com 

 
 
 
CAUTION! 
The transmitter unit contains a light-emitting diode located in the optical connector. This device emits 
invisible infrared electromagnetic radiation that can be harmful to human eyes. The radiation from this 
optical connector, if viewed closely without any protection, may cause instantaneous damage to the retina 
of the eye. Direct viewing of this LED should be avoided at all times. 
 

 
 

SECTION 2 

INSTALLATION INSTRUCTIONS 

 

                                                                                                                                                               

                

                              

 

                

FIGURE 2: PSACV1 Power Supply                                FIGURE 3: VCA1100 Data Cable 

 

 
 
INSTALLATION PROCEDURE 

 

The VersiVision FVT1100 and FVR1100 Series fiber optic video modems can be used with RS-485/RS-422 
and RS-232 data protocols. Simply set the mode of operation with the internal DIP switches and then connect 
the signal, power supply, and fiber optic cables between the two units. There are indicator LEDs on the units for 
monitoring the real-time status of video, power, and data. The following instructions describe the typical 
installation procedure and the function of the LED indicators located on each unit. 
 

1.

 

Connect the video source (camera) to the video input BNC connector on the FVT1100 transmitter unit 
using coaxial cable. 

2.

 

Connect the video output BNC connector on the FVR1100 receiver unit to the video monitor using 
coaxial cable. 

3.

 

Connect the fiber optic cable between the transmitter and receiver devices. 

4.

 

See page 8 for instructions on connecting the data cable 

5.

 

Apply the power supply to both the transmitter and receiver using the PSACV1 power supply provided. 
Note:  If using any of the FVR1100M modules, power is provided from the integral power supply of the 
FVC14 chassis. 

6.

 

When the power is applied, the red POWER LED will light, indicating the presence of operating power. 
The green VIDEO LED and the blue DATA LED will give an indication as stated in the following page. 

7.

 

The link should now be operational. 

 
 

Summary of Contents for FVR1103

Page 1: ...ersitron com VersiVision FVT1100 FVR1100 Series Fiber Optic Video Modems Technical Manual Also covers FVR1100M modules Copyright Aug 2005 VERSITRON Inc 83 Albe Drive Suite C Newark DE 19702 www versit...

Page 2: ...of delivery We will repair or at our option replace parts which during normal usage prove to be defective during the warranty period provided that 1 You call VERSITRON at 302 894 0699 or 800 537 2296...

Page 3: ...CS 5 SPECIFICATIONS 5 6 SECTION 2 INSTALLATION INSTALLATION PROCEDURE 7 SYSTEM DIP SWITCH SETTINGS 8 SYSTEM TERMINAL BLOCK CONNECTIONS 8 INDICATOR LEDs 9 TRANSMITTER AND RECEIVER 9 SECTION 3 TROUBLESH...

Page 4: ...3M Receiver module 1 channel simplex video 1 channel return data Multimode ST 3km installed in Model FVC14 chassis FVR1104M Receiver module 1 channel simplex video 1 channel return data Multimode SC 3...

Page 5: ...re required LED status indicators include video sync present VD data transmitted TD data received RD and power on PWR Physical Characteristics The VersiVision FVT1100 transmitter and FVR1100 receiver...

Page 6: ...6 3 x 1 2 in Shipping Weight 4 4kg Construction Aluminum Finish Black Paint INDICATOR Module Green Video Sync Present Red Power On Blue Data Transmitted Received OPTICAL POWER BUDGET Transmitter Recei...

Page 7: ...Ds on the units for monitoring the real time status of video power and data The following instructions describe the typical installation procedure and the function of the LED indicators located on eac...

Page 8: ...Data Input Output Connector RS 485 2 wire Red Wire Signal being transmitted or received over fiber Blue Wire Signal being transmitted or received over fiber RS 485 Connection Camera Site Using the VCA...

Page 9: ...ne data LED on each unit One labeled as Power or PWR lights when operating power is present Another labeled as Video or VID lights when the video input output signals are detected The other one labele...

Page 10: ...or has too much attenuation Next be certain to check all connections and assure that inputs and outputs are not intermixed and the transmitter and receiver are not connected incorrectly DATA LINK Even...

Page 11: ...11 www versitron com FIGURE 4 VersiVision FVT110x FVR110x Connection Layout...