DIP Switch Settings: 

DIP 1 ON = LFP is enabled 

DIP 1 OFF = LFP is disabled 

DIP 2 OFF + DIP 3 OFF + DIP 4 OFF = Auto-Negotiation 

DIP 2 ON + DIP 3 OFF + DIP 4 OFF = Tx: 100M, Full-Duplex 

DIP 2 ON + DIP 3 OFF + DIP 4 ON = Tx: 100M, Half-Duplex 

DIP 2 ON + DIP 3 ON + DIP 4 OFF = Tx: 10M, Full-Duplex 

DIP 2 ON + DIP 3 ON + DIP 4 On = Tx: 10M, Half-Duplex 

 