11
www.versitron.com
3 OPERATION
3.1 Introduction
This chapter contains a description of the operating controls and indicators associated with
the telephone modems. Since the F271XA is designed for continuous and uninterrupted operation,
there are no setting requirements after the unit is operational. Once the unit is powered up it should
remain in service as long as required.
3.2 Status Indicators
There are five indicators used on the F271XA: Link Status(Link), Transmit Data(TX),
Receive Data(RX), System Status(System), and a multi-function LED for the telephone port (see
Table 7 for descriptions).
Table 7: Status Indicators
LEDs*
Color
Function
Link
Green
Indicated the remote link is active and synchronized
TX
Green
Indicates transmit data
RX
Green
Indicates receive data
System
Green
Indicates System is active and configured (ready for operation)
1
Red
Indicates the following :
Off: Phone is On-Hook
On: Phone is either Off-Hook or Call is in progress
Flashing: Phone is ringing.
* See Table 2 for LED mapping