Versiton SF70460MP Installation Manual Download Page 21

-21- 

2.9 Making Fiber Connection 

The dual-speed  SFP slots, Port  3  and  Port  4 must be installed  with an SFP fiber transceiver for making fiber 

connection.   

 

 

 

Types of the SFP Fiber transceivers supported: 

  1000Mbps based 1000BASE-X SFP transceivers 

  100Mbps based 100BASE-FX SFP transceivers 

 

Installing SFP Fiber Transceiver 

To install an SFP fiber transceiver into SFP slot, the steps are: 

1.  Turn off the power to the switch. 

2.  Insert the SFP fiber transceiver into the SFP slot. Normally, a bail is provided for every SFP transceiver. 

Hold the bail and make insertion. 

3.  When the SFP transceiver is seated securely in the slot, place the bail in lock position. 

 

Connecting Fiber Cables 

LC connectors are commonly equipped on most SFP transceivers. Identify the TX and RX connector before 

making cable connection. The following figure illustrates a connection example between two fiber ports: 

Summary of Contents for SF70460MP

Page 1: ...1 SF70460MP 4 Port 10 100 1000Base Managed PoE PoE Switch Installation Guide v1 00 June 2016 VERSITRON Inc 83 Albe Drive Suite C Newark DE 19702 www versitron com...

Page 2: ...ement is subsequent to receipt of your product at our facility and our diagnostic evaluation and review of the unit Advance replacements are not provided as part of the warranty coverage This warranty...

Page 3: ...may not cause harmful interference and 2 This device must accept any interference received including the interference that may cause undesired operation CE NOTICE Marking by the symbol indicates comp...

Page 4: ...ng UTP Connections 20 2 9 Making Fiber Connection 21 2 10 Making PoE PSE Connections PoE Model 23 1306B2 11 LED Indication 24 3 Manage the Device 26 3 1 IP Address Password 26 3 2 Configuring IP Addre...

Page 5: ...5 5 Redundant Ring Application 40 5 1 Auto Multi Ring Technology for 4 Port Switch Mode 40 5 2 Redundant Ring Applications with industrial standard RSTP protocol 41...

Page 6: ...he following network ports Two 10 100 1000Mbps Gigabit copper ports Two dual speed SFP slots for 100Base FX 1000Base X The device features the following function modes Dual media converter mode Dual m...

Page 7: ...ure and configured port link down Green Ethernet power saving 802 3az Energy Efficient Ethernet EEE support Optional high power PoE PSE function on copper ports Management HTTP HTTPS SSHv2 CLI telnet...

Page 8: ...8 1 2 Product Panels The following figure illustrates the front panel and rear panel of the device Front panel PoE Model Front panel Standard Model...

Page 9: ...3u 1000Base T Connectors Shielded RJ 45 jacks Pin assignments Auto MDI MDI X detection Configuration Auto negotiation or software control Transmission rate 10Mbps 100Mbps 1000Mbps Duplex support Full...

Page 10: ...ength 9 6K bytes IP Multicast groups 8192 supported Flow control IEEE 802 3x pause frame base for full duplex operation Back pressure for half duplex operation Terminal Block Connector DC power input...

Page 11: ...Panel mounting optional Environmental Operating Temperature Typical 30 75 Storage Temperature 40 85 Relative Humidity 5 90 non condensing Electrical Approvals FCC Part 15 rule Class A CE EMC CISPR11...

Page 12: ...ug the product from the electrical outlet and replace the part or contact your trained service provider The power cable extension cable or plug is damaged An object has fallen into the product The pro...

Page 13: ...re The steps to mount the switch onto a DIN rail are 1 Install the mounting bracket onto the switch unit as shown below 2 Attach bracket to the lower edge of the DIN rail and push the unit upward a li...

Page 14: ...14 Dimensions...

Page 15: ...ng bracket supports mounting the switch on a flat surface securely The mounting steps are 1 Install the mounting bracket on the switch unit 2 Screw the bracket on the switch unit 3 Screw the switch un...

Page 16: ...16 Dimensions...

Page 17: ...ecifications Applications Power per PSE port DC working voltage General 8V 60VDC PoE 15 4W max 45V 57VDC Typical 48V High power PoE PoE 35W max 45V 57VDC 52V up for 35W WARNING The 48VDC power supply...

Page 18: ...Vdc connections Alarm Relay output pins and logic Pin 4 5 Alarm relay output NO Normal Open contacts Open normal Shorted Alarm NO NO Pin 5 6 Alarm relay output NC Normal Closed contacts Shorted normal...

Page 19: ...the switch without turning off the power Check whether the network is recovered The button can also be used to restore the software configuration settings to factory default values The operations are...

Page 20: ...e for MDI to MDI X connection It simplifies the cable installation Auto negotiation Function The ports are featured with auto negotiation function and full capability to support connection to any Ethe...

Page 21: ...ber transceiver into SFP slot the steps are 1 Turn off the power to the switch 2 Insert the SFP fiber transceiver into the SFP slot Normally a bail is provided for every SFP transceiver Hold the bail...

Page 22: ...s for configuring port speed via software for SFP Port 9 and Port 10 The options are Auto Auto detection for the type of the installed SFP transceiver by reading DDM data 100Mbps transceiver Non auto...

Page 23: ...airs 4 5 7 8 of the cable The maximum distance supported is 100 meters 3 The power voltage supplied to the switch must be within the range as specified in section 2 5 to make the PoE function work pro...

Page 24: ...itialization and diagnostics G Y BLINK Initialization completed with diagnostic error or system error found during normal operation Green ON Initialization completed with no error operating in 2MC mod...

Page 25: ...rt link status Green ON Port link is established No traffic Green BLINK Port link is up and there is traffic OFF Port link is down Port 3 Port 4 SPEED_LED Port speed link status Green ON A 1000Mbps li...

Page 26: ...2 255 255 255 0 The device uses local authentication instead of RADIUS authentication with factory defaults Fixed Username admin Default password No password is required with factory default However t...

Page 27: ...sers Delete user_name Refer to Operation manual for telnet management 3 3 Configuring IP Address via Web Interface Start Web Browser Start your browser software and enter the default IP address for th...

Page 28: ...28 No password is required Click OK to login into the device Web Page after a Successful Login Select Configuration System IP to configure IP address Configuration Description...

Page 29: ...s enabled DUT will relay DNS requests to the current configured DNS server on DUT and reply as a DNS resolver to the client device on the network Save Click to save the changes Reset Click to undo any...

Page 30: ...tination ipv6_addr SNMP Trap Authentication Failure enable disable SNMP Trap Link up enable disable SNMP Trap Inform Mode enable disable SNMP Trap Inform Timeout timeout SNMP Trap Inform Retry Times r...

Page 31: ...to access to SNMPv3 agent USM User based Security Model user table for SNMPv3 VACM View based Access Control Model Viewer table for SNMPv3 Group table for SNMPv3 Accesses group table for SNMPv3 3 6 S...

Page 32: ...tication Client MIB RFC 5519 Multicast Group Membership Discovery MGMD MIB IEEE 802 1 MSTP MIB IEEE 802 1AB LLDP MIB IEEE 802 1X Port Access Entity PAE MIB TIA 1057 LLDP Media Endpoint Discovery MED M...

Page 33: ...rating Mode Configuration One setting switch SW is provided for operating mode configuration as shown below The functions of the SW switch settings are SW1 1 Hardware 1 The operating mode is determine...

Page 34: ...LFPT function is disabled 1 SW ON 0 SW OFF LFPT Link Fault Pass Through function LFPT Function A media converter performs frame forwarding between two port segments The port segments may be different...

Page 35: ...Software configuration F2F MC Management configuration 1 Available Available LFPT SW4 setting Software configuration Port operating mode Auto for all ports Software configuration IGMP Disabled Softwa...

Page 36: ...s dual media converter mode As configured the device becomes two media converters in one box Port 1 and Port 3 are ports of MC1 converter Port 2 and Port 4 are ports of MC2 converter Both media conver...

Page 37: ...Port 2 have no logic connection to Port 3 and Port 4 under this mode Multi mode fiber MMF to single mode fiber SMF conversion is the most popular application with this operating mode LFPT function op...

Page 38: ...uplink Trunk port P3 4 is LACP compliant Both P3 and P4 are operating at the same time normally When any is in link fault the other will take over the transmission duty for both MC1 and MC2 LFPT func...

Page 39: ...TP HTTPS SSHv2 CLI telnet CLI console SNMP v1 v2c v3 RMON DHCP DHCPv6 client DHCP relay DNS client NTPv4 IPv6 support System Syslog Configuration down upload Software upload Security functions NAS 802...

Page 40: ...tch It is also able to work with RSTP support concurrently in the switch Some basic information is Supports up to two rings in one switch Supports ring member status monitoring for up to 100 member sw...

Page 41: ...standard RSTP protocol It also can be done to support a ring connection using industrial standard RSTP function and establish a backup path In case that any link failure occurs the backup path can li...