Versamatic VDA Service & Operating Manual Download Page 2

vda050710sdsm-rev0419

1

 • Surge Dampeners

www

.

versamatic

.

com

IMPORTANT

Read the safety warnings and instructions in this manual 

before pump installation and start-up. Failure to comply with 

the recommendations stated in this manual could damage the 

pump and void factory warranty.

When used for toxic or aggressive fluids, the pump should 

always be flushed clean prior to disassembly.

Airborne particles and loud noise hazards. Wear eye and ear 

protection.

Before maintenance or repair, shut off the compressed air line, 

bleed the pressure, and disconnect the air line from the pump. 

Be certain that approved eye protection and protective clothing 

are worn at all times. Failure to follow these recommendations 

may result in serious injury or death.

When the pump is used for materials that tend to settle out 

or solidify, the pump should be flushed after each use to 

prevent damage. In freezing temperatures the pump should be 

completely drained between uses.

Before pump operation, inspect all fasteners for loosening 

caused by gasket creep. Retighten loose fasteners to prevent 

leakage. Follow recommended torques stated in this manual.

CAUTION

WARNING

Nonmetallic pumps and plastic components are not UV 

stabilized.  Ultraviolet radiation can damage these parts and 

negatively affect material properties. Do not expose to UV light 

for extended periods of time.

In the event of diaphragm rupture, pumped material may enter 

the air end of the pump, and be discharged into the atmosphere. 

If pumping a product that is hazardous or toxic, the air exhaust 

must be piped to an appropriate area for safe containment.

This pump is pressurized internally with air pressure during 

operation. Make certain that all fasteners are in good condition 

and are reinstalled properly during reassembly.

Take action to prevent static sparking. Fire or explosion can 

result, especially when handling flammable liquids. The pump, 

piping, valves, containers and other miscellaneous equipment 

must be properly grounded.

Safety Information

Summary of Contents for VDA

Page 1: ...pp Inc A Unit of IDEX Corporation Copyright 2019 Warren Rupp Inc All rights reserved SERVICE OPERATING MANUAL ORIGINAL INSTRUCTIONS 800 North Main Street Mansfield OH 44902 USA Phone 419 526 7296 www...

Page 2: ...es the pump should be completely drained between uses Before pump operation inspect all fasteners for loosening caused by gasket creep Retighten loose fasteners to prevent leakage Follow recommended t...

Page 3: ...CIFICATIONS 1 Dimensional Drawings SECTION 2 INSTALLATION OPERATION 2 Principle of Pump Operation Service Typical Installation Guide SECTION 3 EXPLODED VIEW 4 Composite Drawings Parts List Material Co...

Page 4: ...19 3 Surge Dampeners www versamatic com DA05 1 2 NPT BSP THREADED PORT 1 2 NPT BSP THREADED PORT DA07 3 4 NPT BSP THREADED PORT 3 4 NPT BSP THREADED PORT VDA10 VDA07 VDA05 Metallic and Non Metallic Di...

Page 5: ...n PTFE 35 F 31 C 212 F 100 C Nitrile 10 F 23 C 190 F 88 C INSTALLATION START UP Locate the unit in the discharge piping near the pump The dampener will operate in any position However when used with l...

Page 6: ...st air causing the pump to cycle erratically or stop operating Water in the air supply can be reduced by using a point of use air dryer Air Inlet And Priming To start the pump slightly open the air sh...

Page 7: ...amatic com Composite Repair Parts Drawing Supplied with regulator Nameplate location 12 15 11 3 9 10 15 10 9 4 6 1 13 13 2 5 8 8 5 2 7 Diaphragms must be installed as shown with convolutions facing th...

Page 8: ...1 070 115 Capscrew Hex Flange 5 16 18 x 3 00 6 171 070 308 Capscrew Hex Flange 5 16 18 x 3 00 6 171 070 330 Capscrew Hex Flange Metallic VDA05 only 2 10 171 069 115 Capscrew Hex Flange 5 16 18 x 2 5 2...

Page 9: ...y conformance EN809 2012 Ce materiel est fabriqu selon les normes harmonis es suivantes afin d en garantir la conformit Este producto cumple con las siquientes directrices de la comunidad europa Diese...