Clearance and cabinetry dimensions
A
B
C
D
C
H
J
I
F
G
E
Clearance and cabinetry dimensions
(inches (mm))
A
minimum clearance from rear edge of cutout to:
nearest combustible surface
2 3⁄16” (55)
B
minimum clearance from glass surface to:
overhead cabinet centered above the cooktop (unprotected)*
overhead cabinet centered above the cooktop (protected)*
30 ” (762)
24 ” (610)
C
minimum clearance from side edges of
cutout
to:
nearest combustible surface
3 3⁄16” (80)
D
minimum distance from front edge of cutout to:
front edge of counter
13⁄8” (35)
E
minimum clearance from countertop to:
overhead cabinet not directly above the cooktop
18” (457)
F
minimum distance between cabinets either side of the cooktop
36” (915)
G
maximum depth of overhead cabinetry
13” (330)
H
minimum clearance below top of countertop to:
top of oven installed below cooktop (see Fig.1 and Note #3 following)
top of drawer or other obstruction below cooktop (see Fig.2)
4¾
” (120)
4¾
” (120)
I
maximum distance from right edge of cutout to center of junction box
30” (762)
J
minimum clearance below top of countertop to junction box
9” (230)
* See Notes #1 and #2 following.
** This is to allow for adequate slack in the 4’ conduit fi tted on the cooktop.
WARNING!
This cooktop requires
adequate supply of fresh,
cool air to fully function.
The base of the cooktop
must have direct
unrestricted ventilation to
the room where the
cooktop is installed. Follow
the requirements below.
10