INJECTORS TABLE
(1) Power calculated only with inner crown operating
(2) Power calculated with inner and outer crowns operating
BURNERS
NOMINAL POWER
BTU/hr
REDUCED POWER
BTU/hr
LP/PROPANE
11" W.C.P.
NATURAL GAS
4" W.C.P.
Ø injector
[1/100 mm]
Ø injector
[1/100 mm]
Semi-rapid (SR)
8000
1500
85
139
Triple ring (TR)
12000
5000
102
170
Dual (D)
Inner crown
2800
(1)
1100 (1)
50
(no. 1 central)
80
(no. 1 central)
Outer crown
17000 (2)
6500 (2)
80
(no. 2 outer)
139
(no. 2 outer)
Oven burner (left)
13000
1500
109
180
Oven burner (right)
9000
1400
88
145
Broil burner (left)
8500
-
88
146
Broil burner (right)
8000
-
83
140
2
Fig. 2.6a
Fig. 2.6b
Fig. 2.6c
Semi-rapid burner
Triple ring burner
Dual burner
OPERATIONS TO BE
PERFORMED WHEN
SUBSTITUTING THE
INJECTORS
•
Remove the pan supports, the burner
caps and the flame spreaders.
•
Using a wrench substitute the nozzle
injectors “
J
1
”, “
J
2
”, “
J
3
” and “
J
4
”
(figs. 2.6a, 2.6b, 2.6c) with those
most suitable for the kind of gas for
which it is to be used.
•
Refit the flame spreaders, the burner
caps and the pan supports.
The burners are conceived in such a
way so as not to require the regulation
of the primary air.
J
2
J
3
J
4
J
1