background image

 

Blood Pressure 
Sensor 

(Order Code BPS-BTA)  

The Vernier Blood Pressure Sensor is used to measure systemic arterial blood pressure 

in humans (non-invasively). When used with Logger 

Pro

®

 3.4 or newer,  

Logger Lite

® 

1.3.1 or newer, or LabQuest

®

 App 1.2 or newer, it can measure mean 

arterial blood pressure and calculate both the systolic and diastolic blood pressure 

using the oscillometric method.  

The following is a partial list of activities and experiments that can be performed 

using this sensor. 

 

Measure blood pressure before and after exercise. 

 

Measure blood pressure while sitting or standing. 

 

Compare blood pressure after voluntary isometric contractions (weight lifting) 

and a rhythmic activity such as running or biking. 

 

Investigate how digestion affects blood pressure. 

 

Study the effect of caffeine on blood pressure. 

 

Compare blood pressure between smokers and non-smokers. 

What is Included with the Blood Pressure Sensor? 

 

Blood Pressure Sensor 

 

Standard adult size adjustable cuff (27 cm to 39 cm)  

 

Bulb pump (with release valve) 

How the Blood Pressure Sensor Works 

The active sensor in this unit is a Honeywell SSC Series pressure transducer. The 

sensor produces an output voltage that varies with the pressure measured in the cuff. 

It includes special circuitry to minimize errors caused by changes in temperature. We 

also provide a filtering circuit that conditions the signal from the pressure transducer. 

The output voltage from the Blood Pressure Sensor is linear with respect to pressure. 

 

This sensor is equipped with circuitry that supports auto-ID. When used with 
LabQuest

®

 2, LabQuest

®

, LabQuest

®

 Mini, LabPro

®

, Go!

®

 Link, SensorDAQ

TM

,  

TI-Nspire™ Lab Cradle, or EasyLink, the data-collection software identifies the 
sensor and uses pre-defined parameters to configure an experiment appropriate to the 
recognized sensor. 

 2

Collecting Data with the Blood Pressure Sensor 

This sensor can be used with the following interfaces to collect data. 

 

Vernier LabQuest 2 or original LabQuest as a standalone device or with a 

computer 

 

Vernier LabQuest Mini with a computer 

 

Vernier LabPro with a computer 

 

Vernier Go!Link 

 

Vernier EasyLink

® 

(with TI-Nspire handhelds only) 

 

Vernier SensorDAQ 

 

TI-Nspire™ Lab Cradle 

 

Here is the general procedure to follow when using the Blood Pressure Sensor: 
1.  Connect the Blood Pressure Sensor to the interface. 
2.  Start the data-collection software. 
3.  The software will identify the Blood Pressure Sensor and load a default data-

collection setup. You are now ready to collect data. 

Data-Collection Software  

This sensor can be used with an interface and the following data-collection software. 

 

Logger 

Pro

  This computer program is used with LabQuest 2, LabQuest, 

LabQuest Mini, LabPro, or Go!Link. 

 

Logger Lite

  This computer program is used with LabQuest 2, LabQuest, 

LabQuest Mini, LabPro, or Go!Link. 

 

LabQuest App

  This program is used when LabQuest 2 or LabQuest is used as a 

standalone device. 

 

DataQuest™ Software for TI-Nspire™

  This calculator application is for the 

TI-Nspire handheld or computer software. 

 

LabVIEW

  National Instruments LabVIEW™ software is a graphical 

programming language sold by National Instruments. It is used with SensorDAQ 

and can be used with a number of other Vernier interfaces. See 

www.vernier.com/labview for more information. 

NOTE: 

Vernier products are designed for educational use. Our products are not 

designed nor are they recommended for any industrial, medical, or commercial 

process such as life support, patient diagnosis, control of a manufacturing process, or 

industrial testing of any kind. 

Reviews: