Page | 16
small particles which can be easily flushed down the drain.
If the cutter motor is initially stalled by bottles blocking the blades, the invertor will reverse
the blades and attempt to cut through the blockage again. This will be attempted three
times before a
‘Blocked Blade’ fault is displayed. At which point the lid is to be opened
and the blockage removed.
Approximately three-quarters of the way through the cycle the pump restarts to give a
dilution flush of an additional 12 litres (+/- 10%) to the tub and its contents.
At the same time the inlet solenoid valve closes thus preventing additional pumped water
from reaching the drain diaphragm, as the inlet solenoid valve is closed and the outlet
solenoid valve opens which allows the pressurised water behind the drain diaphragm valve
to dissipate. This allows the drain diaphragm to open and the contents of the tub to run to
the drain.
During this period, the motor will initiate for a few brief seconds. This will dissipate any
pulp particles from the blades and allow them to be washed to the drain.
Also at this point the deodoriser valve is opened and a small quantity of deodoriser is
dispensed from the storage reservoir into the chamber removing any odours that may be
present. In the event of the deodoriser reservoir being empty, the cycle will continue but
the icon on the display will indicate the tank is empty and requires re-filling.
Vernacare recommend the use of Vernacare disposal unit deodoriser
(902DL1000, 902DL2000, 902SD1000, 902SD2000).
The water pump then stops, the outlet solenoid valve closes a second later and then the
overall cycle program ends. The display will indicate `End`.
The will remain in this condition with the lid locked until the foot sensor is
operated. When the infra red beam is broken by the insertion of the operator’s foot into
the foot well at the bottom front of the machine, the lid lock disengages and the lid
actuator opens the lid.
Normal Cycle Sequence
Pump
ON ON
OFF
ON
ON ON
ON ON ON
Motor Forward
OFF
ON
ON
ON ON
ON
OFF
ON
OFF
Motor Speed 1 (55Hz)
OFF
ON
ON
OFF OFF OFF OFF OFF OFF
Motor Speed 2 (66Hz)
OFF OFF OFF
ON
ON
ON
OFF
ON
OFF
Deodoriser Valve
OFF OFF OFF OFF
ON
OFF OFF OFF OFF
Inlet Solenoid
ON ON
OFF OFF OFF OFF OFF OFF OFF
Outlet Solenoid
OFF OFF OFF
ON
ON
ON ON
ON
ON
Cy
cle
E
nd
Ste
p
9
(120
s)
Ste
p
8
(114
s)
Ste
p
7
(105
s)
Ste
p
6
(104
s)
Ste
p
5
(103
s)
Ste
p
4
(9
4s)
Ste
p
3
(4
6s)
Ste
p
2
(1
7s)
Ste
p
1
(2
s)
St
ar
t Cy
cle