35

tOuCh sCReeN RemOte CONtROl OpeRAtION

the flame height according to the difference between the 

Set temperature and the Room temperature. There is no 

manual flame height adjustment. The fan speed will also 

automatically adjust if turned on.

NOte:

 When entering the Smart Mode

®

 thermostat func-

tion  there  will  be  a  10  second  delay  for  the  flame  and 

blower adjustment. When Smart Mode

®

 thermostat oper-

ates automatically there can be up to a 3 minute delay for 

flame/blower adjustment. Smart Mode

®

 thermostat checks 

temperatures every 3 minutes. Also see AUX Control.
1.  When Set Temp. is 3° F or higher than Room Temp., 

flame height will be on High.

2.  When  Set  Temp.  is  2°  F  higher  than  Room  Temp., 

flame height will be on Medium.

3.  When  Set  Temp.  is  1°  F  higher  than  Room  Temp., 

flame height will be on Low.

4.  When Set Temp. is equal to Room Temp., flame height 

does not change (stays on low).

5.  When Set Temp. is lower than Room Temp., the fire-

place will be shut off.

6.  When  Set  Temp.  is    1°  F  higher  than  Room  Temp., 

again the flame height will be on Low.

7.  the  fan  speed  follows  the  flame  height,  if  the  fan  is 

turned on.

To  exit  Smart  Mode

®

  thermostat  and  shut  off  the  fire-

place;
  a. push and hold the THERMO buttons for 3 sec-

onds, Or

  b. press the OFF button, Or

  c. slide down on the arrow buttons.

To shut off the Smart Mode

®

 thermostat option and return 

to regular thermostat mode, press and hold the THERMO 

button and the ON/UP button at the same time for 3 sec-

onds again.

Blower speed Control

Figure 43

NOte:

 Blower will only work with 

flame on.
The blower speed control function 

is used to adjust the speed of the 

blower connected to the Signature 

Command System. There are four 

speed  levels,  Off,  Low,  Medium, 

High.
1.  Press the FAN button to enter 

the blower speed control mode. 

The fan icon will start flashing.

2.  Press the ON/up and OFF/down button to increase/de-

crease the blower speed.

3.  Press the fan button again to confirm the speed set-

ting. If the fireplace is on, the blower speed will take 

effect right away; if the fireplace is off, the receiver will 

remember this setting and the blower is still off (see 

blower On Delay and Off Delay in the next section).

4.  After the signal is sent, the ON/up and OFF/down but-

tons become flame height controller again.

5.  When the fan button is flashing, slide up and down on 

the arrow buttons will turn the blower speed to High 

or Off directly without pressing the fan button again to 

confirm.

6.  If the blower  is turned on using  the FAN button, the 

blower  speed  will  adjust  automatically  when  using 

Smart Mode (See Smart Mode section).

Blower On Delay time and Off Delay time setup

Figure 44

1.  Hold the FAN button for 3 sec-

onds  until  two  numbers  ap-

pear  on  the  LCD  screen.  The 

left number is blower On Delay 

and the right number is blower 

Off Delay Time.

2.  When the first number is flash-

ing,  use  the  ON/up  button  to 

set the desired On Delay Time 

from 0 to 15 min.

3.  Press  the  OFF/down  button 

to jump to the Off Delay Time 

setup.

4.  When  the  second  number  is 

flashing, use the ON/up button again to set the desired 

Off Delay Time from 0 to 15 min.

5.  Press the OFF/down button again to finish the setup 

and the new settings will be transmitted to the receiv-

er.

6.  The  default  settings  are  5  minutes  for  the  On  Delay 

Time and 8 minutes for the Off Delay Time, as shown.

light Brightness Control

Figure 45

The light brightness control func-

tion is used to adjust the bright-

ness of the light bulbs connected 

to the AC module on the Signa-

ture  Command  System.  There 

are  four  light  brightness  levels 

defined: Off, Low, Medium, High
1.  Press the LIGHT button to en-

ter the light brightness control 

mode.  The  LIGHT  icon  will 

start flashing.

2.  Press  the  On/up  and  OFF/

down buttons to increase/de-

crease  the  light  brightness 

(Off-Low-Medium-High).

FP2656
blower delay setup

FP2657
Light bright control

Figure 45

Figure 44

FP2655
blower speed control

Figure 43

Summary of Contents for VC31CDVINTSC

Page 1: ...services or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier This applianc...

Page 2: ...ff Tool 19 Electrical Installation 20 Electrical Wiring 20 Log Placement 21 Rock Wool Placement 21 Decorative Glass Glass Bead Installation 24 Operating Instructions 25 For Your Safety Read Before Lig...

Page 3: ...installed by a qualified service person with glass door properly seated and sealed combustion leakage can occur CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the fl...

Page 4: ...from outside of the dwelling through the vent pipe These appliances have been tested by CSA and found to comply with the established standards for DIRECT VENT GAS FIREPLACE HEATERS in the USA and Cana...

Page 5: ...certified without deration for elevations up to 4 500 feet 1 370 m above sea level For elevations above 4 500 feet 1 370 m in USA installation must be in accordance with the current ANSI Z223 1 NFPA 5...

Page 6: ...ireplace Insert 2256QE 560 mm 115 6QE 303 mm 1056 257 mm 2 6QE 56 mm 55 6QE 144 mm 1656 410 mm 24 6QE 621 mm 2756 689 mm 256M 57 mm 2156QE 535 mm 4164 ICFDV insert dims insert dimensions Figure 2 VC31...

Page 7: ...tion and clearances are subject to local building codes INSERT APPLICATIONS Before installing the gas fireplace insert consider the functioning needs of the fireplace Confirm the size of the fireplace...

Page 8: ...g If it does it is considered a mantel and must meet the mantel requirements listed in this manual FP2964 Figure 3 Mantel Clearances NOTE Side clearance to combustibles is 10 254 mm from opening wheth...

Page 9: ...BOX DIMS 22 6 568 mm 20 6M 527 mm 16 6M 426 mm 30 6M 781 mm 29N m 759 mm with control box and bracket removed REMOVE COMMAND CENTER BRACKET In order to fit insert into a smaller opening the command ce...

Page 10: ...well ventilated OPEN ALL WINDOWS DURING INITIAL BURN OFF CURING PHASE Burn your insert for at least six 6 hours on HIGH the first time you use it Place the fan in the OFF position during this time Fp...

Page 11: ...fore attempting installation Failure to do so could result in serious injury property damage or loss of life Operation of improperly installed and maintained venting system could result in serious inj...

Page 12: ...d to resize orifice for use at high altitude contact your dealer High Temp Silicone FP2948 exhaust pipe 3 and 3 UL 1777 Gas Liner Apply high temperature silicone to lines on both ends and secure with...

Page 13: ...let Recommended block off plate noncombustible metal Prevents odors from chimney entering room UL 127 Solid Fuel Z C Fire box Figure 11 Inlet and Exhaust Reline NOTE You may use a reline configuration...

Page 14: ...els and retainers from packaging 2 Remove two 2 screws on each side of front edge of chamber 3 Install one 1 front brick retainer bracket on each side with the screws removed in Step 2 4 Carefully set...

Page 15: ...celain Panel Kit Contemporary Porcelain Panel Kit Contemporary Support Bracket Supplied w Contem porary Kit Use Self tapping Screws Existing Support Figure 14 1 Remove porcelain panels and hardware fr...

Page 16: ...e closed Retighten screws NOTE For propane LP units the baffle assembly is com pletely removed for venting under 20 ft 6 m For venting 20 ft and above the baffle assembly is to be used with only one 1...

Page 17: ...ou must reduce incoming gas pressure to between 11 and 13 inches of water If you do not reduce incoming gas pressure burner system regula tor damage could occur Install external regulator with the ven...

Page 18: ...contaminants This keeps them from going into the burner system gas con trols If sediment trap drip leg is not installed or is installed wrong burner system may not run properly NOTE The gas line conn...

Page 19: ...ater and soap solution or a gas sniffer 4 To check gas pressures at valve turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point Turn unit to high F...

Page 20: ...electrical supply Electricity is only needed to operate blower Verify proper operation after servicing Electrical connections should only be performed by a qualified licensed electrician Main power mu...

Page 21: ...s will affect the flame and the flame appearance NOTE Embers may be added to entire burner area in front of grate to hide burner and log support brackets Ember Material Area LG1132 Figure 23 Ember Mat...

Page 22: ...log on the right grate tine by placing the notch on the bottom of the log on the rear portion of the grate tine Figure 24 Log 3 LG1125 Figure 25 Log 4 LG1126 Figure 26 5 Install log 3 onto log 2 by pl...

Page 23: ...notch on the bottom of the right side onto the middle or remaining rectangular protrusion on log 2 Figure 27 LG1128 CFDVI log 6 7 Log 6 LG1128 Figure 28 Log 7 8 Install log 6 by placing rectangular no...

Page 24: ...is intended for future use 2 Mix the two 2 bags of decorative glass provided in the kit as desired Lay glass on top of burner and cover burner area with one 1 layer Glass may be used around the perim...

Page 25: ...one Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your finger to push in the master switch Never use tools If the switch will not fun...

Page 26: ...s go to next step 4 Press the master switch to the ON position Within eight 8 seconds it will beep once This indicates the system is ready 5 Press ON button Sparker will spark and pilot flame will lig...

Page 27: ...de and rear brick panels 2 Remove log support bracket by removing two 2 screws in rear and one 1 screw on each side wall FP1940 air shutter part open Air Shutter FP1940 Figure 30 Push Adjustment Lip U...

Page 28: ...grate bar The slide adjustable air shutter has a range of 1 Figure 32 To increase air mixture open the slide adjustment by gently pulling on the lever When lever stops it has reached its maximum adju...

Page 29: ...X Low battery Indication for Transmitter X Child Proof Lock out X LCD Backlight X Security Codes 16 X Countdown 6 hr Timer X Standard Thermostatic Control Mode X Smart Mode Thermostat Auto Flame Blowe...

Page 30: ...n 3 seconds when the master switch Shutoff on the main burner is off RF Remote Receiver Push the RF receiver On Off button on the control board RF OFF On Off Beep once for ON and beep twice for OFF Le...

Page 31: ...Learning GREEN Flashes every 1 sec for 10 sec AC Power On GREEN solid Pressure Switch Failed Power Vent only One RED every 2 sec until manual reset Self Diagnostics Chart The Command Center has a self...

Page 32: ...arrows The blue LED backlight lights up for 8 seconds when any of the touch buttons is pressed The menus include TIMER THERMO LIGHT FAN and AUX Rear Burner Control The adjustment arrows include ON up...

Page 33: ...e Command Cen ter will flash for 10 seconds 4 During the 10 sec onds press the OFF button on the transmitter to learn Another two beeps will be given to confirm a success ful learning Figure 38 TOUCH...

Page 34: ...ireplace will be shut down completely when the timer counts down to zero 6 To exit Timer Mode a Push and hold the TIMER button for 3 seconds Or b Use the OFF down buttons to decrease the Set Time to z...

Page 35: ...d OFF down button to increase de crease the blower speed 3 Press the fan button again to confirm the speed set ting If the fireplace is on the blower speed will take effect right away if the fireplace...

Page 36: ...g is A touch any place in the touch area to bring up the icons then press TIMER but ton and THERMO button at the same time for 3 sec onds The backlight will flash once to indicate that the setting has...

Page 37: ...play is blank 2 Check battery installation or replace batteries 3 LCD display shows funny display 3 Reset the transmitter see Resetting the Transmitter section 4 Appliance does not come on 2 The trans...

Page 38: ...hey will damage the glass surface pilot and burner flames Visually check pilot and burner flames periodically Refer to Figure 48 for typical burner flame Refer to Figure 49 for typical pilot flame CLE...

Page 39: ...Contact dealer where you bought heater 4 Remove rock wool Clean burner and burner ports Figure 51 5 Replace log set and ember according to instructions on Pages 21 23 Replace decorative glass accordi...

Page 40: ...through Battery polarity wrong LED on the Command Center does not show solid green The 5 pin connector on the AC board broken or bent AC plug is plugged to AC mains Battery voltage low Using battery C...

Page 41: ...0304166 VC31LDVI VC31CDVI Gas Fireplace Insert 41 REPLACEMENT PARTS 24 6 1 2 3 4 5 11 12 14 16 39 32 34 33 38 4166 VCFDVI31 parts 17 27 25 26 31 30 29 10 7 8 9 13 15 18 19 20 21 22 11 19 23 40 8 47 48...

Page 42: ...0018 26 Command Center SCS 1 80D0005 80D0005 80D0005 27 AC Module SCS 1 80D0004 80D0004 80D0004 28 Remote Control 1 TSFRSC TSFRSC TSFSC 29 Wire Valve Control Board SCS 1 80D0010 80D0010 80D0010 30 Wir...

Page 43: ...onversion Kits Natural Gas to LP VC31LDVINTSC Kit VCFILPK VC31CDVINTSC Kit ICF30LPK WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically ap...

Page 44: ...TVI 5b Glass Frame Textured Mocha ICF30GTTM 6a Rectangular Double Door Satin Black ICF30R2DSB 6b Rectangular Double Door Vintage Iron ICF30R2DVI 6c Rectangular Double Door Textured Mocha ICF30R2DTM 7a...

Page 45: ...20304166 VC31LDVI VC31CDVI Gas Fireplace Insert 45...

Page 46: ...comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents Only Plea...

Page 47: ...ited 10 year warranty will be void if the appliance is not installed by a qualified installer in accor dance with the installation instructions The limited 10 year warranty will also be void if the ap...

Page 48: ...rendement nerg tique de foyer au gaz nerguide Selon CSA P 4 1 09 Efficiency Ratings Model EnerGuide Ratings D O E Fireplace Efficiency AFUE VC31LDVINTSC 69 0 68 0 VC31LDVIPTSC 72 9 70 4 VC31CDVINTSC 6...

Reviews: