11
UVL Series
Fireplace Screen
The fireplace screen must be in place when the
appliance is operating, and unless other provisions
for combustion air are made, the screen must have
openings for the introduction of combustion air.
5. Remote wall switch
(RN and RP models only)
1. Thread wire through the electrical knockout
located on either side of the fireplace. Do not cut the
wire or insulation on metal edges. Ensure that the
wire is protected. Run the other end to a conve-
niently-located wall receptacle box.
2. Attach the wire to the switch and install the switch
into the receptacle box. Attach the cover plate to the
switch.
3. Connect the wiring to the gas valve. One wire
connects to the ‘TP/TH’ terminal; the other attaches
to the ‘TH’ terminal. (Fig. 10)
NOTE: If any of the original wire as supplied with the
appliance must be replaced, it must be replaced with
a wire of at least a 105
°
(C) temperature rating.
UVL18
UVL24
UVL30
Fig. 8 Positioning logs on grate assembly.
LG112
LG113
PILOT
ON
OFF
LO
HI
TPTH
TH
TP
Control Knob
Piezo Ignitor
Hi/Lo Knob
To Wall Switch
751
Fig. 9 Connecting a wall switch to the valve terminals.
(UVL-R Series only)
LG114