Before You Start
This instruction sheet is ONLY for models listed below. Carefully inspect the contents for shipping damage. If any parts
are missing or damaged, immediately inform the dealer from whom you purchased the part.
Models:
LSTF36, LPF36, LRF36, LLF36, 36STFL, 36PFL, 36RFL, 36LFL, (ST, CL, CR, PF)LDV
Kit Contents:
(1) Blower Assembly
(4) Screws #14 x 3/4
(2) Screws #8 x 1/2 (1) Power Cord
(1) Speed Control
(1) Speed Control Mounting Bracket (2) Wire Ties
(1) Gasket
(2) High Temperature Wire
(4) Rubber Grommets
(1) Thermostatic Sensor (Large screw-in style)
(1) Thermostatic Sensor (Small snap-in style)
Tools Required:
Phillips screwdriver, Small jeweler’s style screwdriver
W
ARNING
Before installing the blower, turn off the fireplace
and allow to cool. Only a qualified service person
should service and repair the fireplace. A qualified
service person should connect and disconnect the
fireplace to gas supply. Follow all local codes.
W
ARNING
Electrical Grounding Instructions:
This appliance is equipped with a three-prong
(grounding) plug for your protection against shock
hazard and should be plugged directly into a prop-
erly grounded three prong receptacle.
CAUTION
Electrical connections should only be performed
by a qualified licensed electrician. Main power
supply must be turned off before connecting fans
to the main electrical power supply or performing
service.
IMPORTANT:
Always check local building codes. This
installation must comply with local regulations as well
as the National Electric Code.
Installation Instructions
Wiring
1. Before installing the blower, wire the receptacle into an electrical circuit. This should be done
before framing the fireplace. Wire with minimum 60° C wire in accordance with prevailing
codes.
2. Remove the external junction box cover by removing the screw
from the left side of the outside firebox wall. Junction box was
installed at the factory.
3. The junction box cover has a factory installed “romex” style strain
relief connector. After connecting the wires, route the wire leads
through this connector. Refer to the wiring diagram in Figure 1.
79D0009 1/13 Rev. 3
&0
*UNCTIONBOXWIRING
Junction Box
120V AC
60Hz
Factory Supplied
Not Supplied
Figure 1
Junction Box Wiring Diagram
Thermostatic Blower
Installation Instructions
Model: BLOTDL