Before You Start

This instruction sheet is ONLY for models listed below. Carefully inspect the contents for shipping damage. If any parts 

are missing or damaged, immediately inform the dealer from whom you purchased the part.

Models:

 LSTF36, LPF36, LRF36, LLF36, 36STFL, 36PFL, 36RFL, 36LFL, (ST, CL, CR, PF)LDV

Kit Contents:

  (1) Blower Assembly 

(4) Screws #14 x 3/4 

(2) Screws #8 x 1/2  (1) Power Cord

  (1) Speed Control 

(1) Speed Control Mounting Bracket  (2) Wire Ties 

  (1) Gasket  

(2) High Temperature Wire 

(4) Rubber Grommets

  (1) Thermostatic Sensor (Large screw-in style) 

(1) Thermostatic Sensor (Small snap-in style)

Tools Required:

 

 

Phillips screwdriver, Small jeweler’s style screwdriver

W

ARNING

Before installing the blower, turn off the fireplace 

and allow to cool. Only a qualified service person 

should service and repair the fireplace. A qualified 

service person should connect and disconnect the 

fireplace to gas supply. Follow all local codes.

W

ARNING

Electrical Grounding Instructions:

This  appliance  is  equipped  with  a  three-prong 

(grounding) plug for your protection against shock 

hazard and should be plugged directly into a prop-

erly grounded three prong receptacle.

CAUTION

Electrical  connections  should  only  be  performed 

by  a  qualified  licensed  electrician.  Main  power 

supply must be turned off before connecting fans 

to the main electrical power supply or performing 

service.

IMPORTANT:

 Always check local building codes. This 

installation must comply with local regulations as well 

as the National Electric Code.

Installation Instructions
Wiring

1.  Before installing the blower, wire the receptacle into an electrical circuit. This should be done 

before framing the fireplace. Wire with minimum 60° C wire in accordance with prevailing 

codes.

2.  Remove the external junction box cover by removing the screw 

from the left side of the outside firebox wall. Junction box was 

installed at the factory.

3.  The junction box cover has a factory installed “romex” style strain 

relief connector. After connecting the wires, route the wire leads 

through this connector. Refer to the wiring diagram in Figure 1.

79D0009  1/13  Rev. 3

&0
*UNCTIONBOXWIRING

Junction Box

120V AC

60Hz

Factory Supplied

Not Supplied

Figure 1

Junction Box Wiring Diagram

Thermostatic Blower 

Installation Instructions

Model: BLOTDL