73D0024
9
KHLDV Series Gas Fireplace
72” (1829 mm)
Minimum
Ceiling
12”
(305 mm)
Max. Depth
2
1
/
2
” Max Depth
(64 mm)
10” (254 mm)
Min.From Opening
16” (406 mm)
Min. From Opening
FP2128
mantel clearances
6”
(152 mm)
Min.
Hearth 8” Min.
(203 mm)
Noncombustible
Hearth Minimum
Fireplace Opening
cLearanceS
cLearanceS to coMBuStIBLeS
ManteL cLearanceS
note: the combustible area above the facing must
not protrude more than 3/4" from the facing. If it does,
it is considered a mantel and must meet the mantel
requirements listed in this manual.
w
arn
In
G
Follow these instructions carefully to
ensure safe installation. Failure to follow
instructions exactly can create a fire
hazard.
the appliance cannot be installed on a carpet,
tile or other combustible material other than
wood flooring. If installed on carpet or vinyl
flooring, the appliance shall be installed on
a metal, wood or noncombustible material
panel extending full width and depth of the
appliance.
FP2128
12"
(305 mm)
16"
(406 mm)
10"
(254 mm)
12" (305 mm)
6" (152 mm)
2
1
/
2
" (64 mm)
FP2204
mantel clearances
Wall
Stud
Insulation
Board
Standoff
Top of Fireplace
Opening
FP2235
Side View
Figure 4 -
Clearances from the mantel, ceiling, and side wall.
6"
5"
3"
2
1
/
2
"
4
1
/
2
"
45°
1"
3
1
/
2
"
FP2129
mantel leg
1
1
/
2
"
FP2129
Fireplace Opening
Figure 5 -
Mantel clearances
top View