background image

9

10005898

Vermont Castings, Majestic Products, DEF33/36, DEFD33/ 36

Electrical Wiring Diagram with Integral Remote Control

Any electrical repairs or rewiring of this unit should be carried out by a licensed electrician in accordance with national
and local codes.

If repairing or replacing any electrical component or wiring,
the original wire routing, color coding and securing locations
must be followed.

Wiring Color Code:
WH =

White

BL =

Black

RE =

Red

Component Identification:

1.

Motor, Variable Speed 12 VDC

2.

Switch ON/OFF

3.

Thermostat

4.

Fan/Heater

5.

Light Socket with Wiring Assem.

6.

Light Bulb, 60 W

7.

Breaker Circuit Manual Reset

8.

Power cord 16/3 HPN with Terminal

9.

Bushing Straight-Thru Strain Relief

10. Cable Tie Nylon, 6" x 1

1

/

8

" Black

11. Bushing Snap 0.875"-0.625"
12. CFM-Majestic Wire Required
13. Receiver
14. Potentiometer Assembly
15. Circuit Board Flame Speed Control

5 BLACK

BLACK

WHITE

7 WHITE

1 BLACK

2 BLACK

3 BLACK

8 WHITE

4 BLACK

6 RED

9 WHITE

BLACK

RED

9 WHITE

6 RED

15

14

4

2

11

8

9

13

7

5

6

3

10

11

4

F

F

O

N/

O

H

C

T

I

W

S

N

N

L

L

OUT

IN 

OUT

IN

HEATER

ELEMENT

T

A

T

S

T’

BREAKER

CIRCUIT

FAN

MOTOR

CONTROL

SPEED 

-

+

MOTOR

FLAME

Summary of Contents for DEF33

Page 1: ...NFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY AN ELECTRICAL SHOCK OR FIRE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE FOR YOUR SAFETY Service must be performed by a qualifie...

Page 2: ...abinet Installations 3 Fireplace Dimensions 4 Electrical Specifications 4 Mantels 5 Framing and Finishing 6 Electrical Connection 6 Hard Direct Wire Connection 6 Installation of DEF33 Logs 7 Installat...

Page 3: ...ireplace again 7 Do not use outdoors 8 This heater is not intended for use in bathrooms laundry areas and similar indoor locations Never locate this appliance where it may fall into a bathtub or other...

Page 4: ...28 7 8 733mm 341 4 870mm C 31 787mm 33 838mm D 16 3 8 416mm 21 533mm E 6 27 64 163mm 6 27 64 163mm F 4 102mm 5 3 8 137mm G 11 1 2 292mm 14 356mm H 221 16 560mm 221 8 562mm I 3 76mm 33 4 95mm Framing...

Page 5: ...the mantel such paint or lacquer must be heat resistant to prevent discoloration J F G H I Mantel Leg Black Surround Face CFM164a O N M L K Side of Combustion Chamber CFM170 Fig 2b Combustible mantel...

Page 6: ...lified electrician may remove the cord connection and wire this unit directly to the household wiring See page 15 Any electrical rewiring of this appliance must be done by a qualified electrician This...

Page 7: ...ogset Installation of DEF36 Logs B116 B115 B119 B118 MVC_002F Fig 5 DEF36 DEFD36 Logset Refer to Figure 5 1 Turn off power to the unit 2 Remove front glass See Glass Removal section or open front door...

Page 8: ...or open glass doors 4 Remove the four 4 screws securing the ember bed in position Two screws 2 are located on either side of the ember bed near the front 5 Examine the bulbs to determine which bulbs...

Page 9: ...ation 1 Motor Variable Speed 12VDC 2 Switch ON OFF 3 Thermostat 4 Fan Heater 5 Light Socket with Wiring Assem 6 Light Bulb 60W 7 Breaker Circuit Manual Reset 8 Power cord 16 3 HPN with Terminal 9 Bush...

Page 10: ...eramic refractory installation Electrical Wiring Diagram without Integral Remote Control Wiring Color Code WH White BL Black RE Red Component Identification 1 Motor Variable Speed 12VDC 2 Switch ON OF...

Page 11: ...ils sur le service Voir les instructions d installation pour heater least 3 feet 0 9m from the front of the cords draping and other furnishings at WARNING Risk of fire keep electrical Servicing WARNIN...

Page 12: ...scontinue colors and products at any time without notice DEF33 36 DEFD33 36 Electric Fireplace 15 19 26 12 11 13 17 14 15 305mm 12 305mm 12 216mm 8 1 2 DIST 216mm 8 1 2 DISTANCE BETWEEN ANCE BETWEEN T...

Page 13: ...ometer 10001639 10001639 10001639 10001639 9 Screen Tinted Plastic Not shown 10005518 10005518 10005954 10005954 10 Flame Generator Assembly 10003350 10003350 10003350 10003350 11 Glass with Gasket 4W...

Page 14: ...Remove the deflector cabinet top from the top radiant face Save the screws and deflector cabinet top to reinstall into the top Radiant panel 3 Open the access Radiant face door then remove the bottom...

Page 15: ...knife as this may expose bare conductor The hot wire is connected to the circuit breaker The neutral wire is connected to the rocker switch and the green ground wire is attached to a ground stud on th...

Page 16: ...estic Products aux pr sentes nomm e la Soci t garantit votre nouveau foyer lectrique Vermont Castings Majestic Products contre tous d fauts de fabrication et de mati res premi res pour une p riode d u...

Reviews: