CRLDV/CLLDV FRAMING
INSTALLATION INFORMATION
20306750
9
Designer Series Direct Vent Gas Fireplace
27
56O
” (699 mm)
(1/2” Drywall)
or
27
6
” (696 mm)
(5/8” Drywall)
46
56
” (1172 mm)
(1/2” Drywall)
or
46” (1168 mm)
(5/8” Drywall)
27
(6
” (708 mm)
46
6
” (1
184 mm)
48
6QE
"
(1224 m
8
556QE
”
(221 mm) Min,
7”
(178 mm)
Min.
4
56O
”
(114 mm)
Min.
Remove box and
Insulation for Top
Vent Confi gurations
Noncombustible
Material
Fold Outer Tabs
and Nail to Framing
Members
Figure 6 -
CRLDV and CLLDV (Corner) Framing
If using 5/8" drywall, remove
framing tabs and re-install
on 2nd set of holes
positioned slightly inwards
If using 5/8" drywall,
remove framing
tabs and re-install
on 2nd set of holes
positioned slightly
inwards
The fi replace must be secured to the fl oor and/or to framing
studs as shown in
Figure 6
. Use four (4) wood screws or
masonry/ concrete screws to secure fi replace to the fl oor.
Use four (4) screws to attach fi replace to framing. The side
brackets or nailing fl anges are designed to accommodate
two wall boards thicknesses, 1/2" or 5/8".
NOTE
Never install combustible materials over
front face of fi replace.
NOTE
The area above and on the sides of the
fi replace must be a noncombustible material.
Figures 5, 6, 7
If using 5/8" drywall, remove
noncombustible supports, rotate
180° and reinstall to achieve
5/8" depth