background image

Decorative Gas Appliance For Installation In Solid Fuel Burning Fireplaces

3311007   11/01  Rev. 1

Vented Gas Logs - Premium Hearth Kits

WARNING

If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.

What To Do If You Smell Gas

• Do not try to light any appliance.

• Do not touch any electrical switch, do not

use any phone in your building.

• Immediately call your gas supplier from

a neighbor’s phone.  Follow the gas
supplier’s instructions.

• If you cannot reach your gas supplier,

call the fire department.

For Your Safety

Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any gas appliance.

Carbon Monoxide Poisoning May Lead To Death

When used without fresh air, gas logs may give off carbon monoxide, an odorless, poisonous gas. Some
people such as pregnant women, people with heart or lung disease, and persons at high altitudes are
more affected by carbon monoxide than others.

Early signs of carbon monoxide poisoning resemble the flu:  Headache, dizziness, and/or nausea.  If you
have these signs, the gas  logs may not be installed or working properly.  Get fresh air at once!  Have the
gas log set and chimney serviced before using it again.

Please record your gas log’s model number
for future reference here:

Note: This model # can be found on the box or
the label attached to the back of the burner pan.

Installation, service, and repair of this appliance must
be performed by a qualified installer, service agency,
company or gas supplier experienced with this type of
gas appliance.

INSTALLER:

Read these instructions completely and carefully
prior to beginning installation.  After installation, leave
these instructions with the owner.

OWNER:

Read these instructions and follow the warnings.
Save this manual for future reference.

Check local codes before installing this log set.  In
some areas of the country, gas log sets are
restricted.

The installation and the provisions for combustion
and ventilation air must conform with the National
Fuel Gas Code, ANSI Z223.1.

Models: A18PHKSN, A24PHKSN, A30PHKSN, A18PHKSP, A24PHKSP, A30PHKSP

                   A18PHKRN, A24PHKRN, A30PHKRN, A18PHKRP, A24PHKRP, A30PHKRP

Certified to ANSI Z21.60 and

CGA 2.26 Standards

f i r e - p a r t s . c o m

Summary of Contents for A18PHKRN

Page 1: ...xide poisoning resemble the flu Headache dizziness and or nausea If you have these signs the gas logs may not be installed or working properly Get fresh air at once Have the gas log set and chimney se...

Page 2: ...PONENT PARTS Only factory authorized components listed in these instructions may be used in accordance with the manufacturer s instructions and all codes and requirements of the authority having juris...

Page 3: ...r log set must be installed in a solid fuel burning fireplace constructed of noncombustible material with a working flue E Solid fuels shall not be burned in the fireplace where your gas log set is in...

Page 4: ...fice 53 20001425 24 30 Orifice 51 20001340 Front Orifice Holder LP 20001670 18 Orifice 60 20001672 24 30 Orifice 57 8 20001727 Inlet Manifold 1 9 3304192 Pressure Regulator 1 10 3304233 Pilot Assembly...

Page 5: ...5 Figure 1A Standard Pilot Kit 1 2 3 9 11 23 24 25 24 25 10 4 14 5 6 8 7 12 13 18 17 16 15 19 20 21 22 fire parts com...

Page 6: ...18 Orifice 53 20001425 24 30 Orifice 51 20001340 Front Orifice Holder LP 20001670 18 Orifice 60 20001672 24 30 Orifice 57 8 20001727 Inlet Manifold 1 9 7522355 ON OFF RS Switch 1 10 20000039 Pilot As...

Page 7: ...7 Figure 1B Remote Pilot Kit 1 2 3 9 21 22 23 22 23 4 12 5 6 8 7 16 15 14 13 17 18 19 20 10 11 fire parts com...

Page 8: ...ding codes Check with your local building department Does your fireplace have a wire mesh screen in place Pre Installation Checklist Yes No Minimum Firebox Dimensions Minimum Gas Fuel Line Manifold Se...

Page 9: ...Figure 2 With the Damper open align the two slots on either side of the cut out on the Damper Stop with the two small holes on the angled portion of the Damper Locking Bracket Attach the Damper Stop w...

Page 10: ...ght a tightly rolled newspaper on one end and place it at the inside front edge of the fireplace Observe the smoke and be sure the vent is properly drawing it up the chimney If the smoke is drawn back...

Page 11: ...Ceramic plaque burner as shown in Figure 5 You may overflow the Vermiculite in front of the pan onto the fireplace floor Do not place any Vermiculite on top directly in front of directly in back of o...

Page 12: ...of the glowing embers at the front of the burner pan Place the other between the two center logs Log Placement Grate And Ember Placement 4 Open the small bag of Ceramic Lava Rock part number 57897 and...

Page 13: ...Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 4 Wait five 5 minutes to clear out any gas If you then smell gas STOP Follow the safety informa tion on page 13 I...

Page 14: ...low 1 STOP Read the safety information on page 13 2 Push in gas control knob slightly and turn clock wise to OFF 3 NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not...

Page 15: ...e you installed the correct orifice into the set Blocked ports low flame only Free the main burner orifice and burner bar ports of any burrs paint or other blockage Troubleshooting Log Set Is Smoking...

Page 16: ...ct to its Vermont Castings Decorative Gas Appliances the Gas Appliance including the Vermont Castings Majes tic Products Company supp lied accessories and components referred to in those paragraphs su...