11
User Guide Kick Lancet
EN
Using the analogue trigger-inputs GATE,
SWITCH and AUDIO
As an alternative to playing KICK LANCET via MIDI, the unit can also be triggered by various
analogue signals. There are three options.
GATE
This jack allows triggering KICK LANCET using a 5 volts gate signal with positive slope. A compatible
trigger signal is generated by multiple analogue sequencers, modular systems and analogue
synthesizers. Beyond that, KICK LANCET has the ability to interpret different voltages of a trigger
signal as dynamics.
The function of the
GATE
jack can be specified by MIDI control command #84. You need to send a
corresponding value (0, 1, 2 or 3) on the set MIDI-channel to KICK LANCET:
CC# 84 Value
Description
0
standard 5V (factory default)
An incoming voltage of approx. 0.5 volts will trigger KICK LANCET at a
fixed volume.
1
standard 5V + accent
A voltage between approx. 0.5 and 5 volts will trigger KICK LANCET at a
fixed volume. Voltages between 5 and 10 volts will trigger a second, fixed
accent volume.
2
standard 5V + dynamic
A voltage between approx. 0.5 and 5 volts will trigger KICK LANCET at a
fixed volume. Higher voltages (5-10 volts) are interpreted dynamically. At
10 volts, the full volume will be reached.
3
dynamic
KICK LANCET will be dynamically triggered, depending on the trigger
voltages, ranging between 0.5 and 10 volts.
Summary of Contents for kick lancet