background image

Note:

For security purposes, each drive tray is locked by default when the storage

shelf is shipped from the factory. To access a hard disk drive, each storage bay
must be unlocked using a T10 screw driver.

Veritas 2U12 49TB Storage Shelf control panel

The Veritas 2U12 49TB Storage Shelf control panel is installed on the front left side
of the storage shelf.

Figure 2-3

Veritas 2U12 49TB Storage Shelf control panel

1

3
4

5

2

36

About the Veritas 2U12 49TB Storage Shelf

Veritas 2U12 49TB Storage Shelf control panel

Summary of Contents for NetBackup 5240

Page 1: ...Veritas NetBackup 5240 Appliance Product Description ...

Page 2: ... written authorization of Veritas Technologies LLC and its licensors if any THE DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID VERITAS TECHNOLOGIES LLC SH...

Page 3: ...site https sort veritas com documents Documentation feedback Your feedback is important to us Suggest improvements or report errors or omissions to the documentation Include the document title document version chapter title and section title of the text on which you are reporting Send feedback to APPL docs veritas com You can also see documentation information or ask a question on the Veritas comm...

Page 4: ...etwork Interface Port locations and speeds 31 Chapter 2 About the Veritas 2U12 49TB Storage Shelf 32 Veritas 2U12 49TB Storage Shelf overview 32 Usable appliance storage capacities 33 Veritas 2U12 49TB Storage Shelf front panel components 34 Veritas 2U12 49TB Storage Shelf control panel 36 Veritas 2U12 49TB Storage Shelf rear components 38 Veritas 2U12 49TB Storage Shelf I O modules 39 Veritas 2U1...

Page 5: ...4 Environmental specifications 59 Protocol standards 60 Regulatory compliance and certification information 61 Product regulatory compliance 61 Product safety compliance 62 Product EMC Compliance Class A Compliance 62 Product ecology compliance 63 Certifications Registrations Declarations 63 Electromagnetic compatibility notices 64 Index 66 5 Contents ...

Page 6: ...tBackup 5240 Appliance overview Features and components of the NetBackup 5240 Appliance NetBackup 5240 Appliance front panel disk drive configurations NetBackup 5240 Appliance front panel USB port NetBackup 5240 Appliance control panel NetBackup 5240 Appliance rear panel 1 Chapter ...

Page 7: ... Master Server or a Media Server It can also be configured as both See Usable appliance storage capacities on page 33 SAS 3 cables connect the NetBackup 5240 Appliance to the storage shelves SAS 3 cables also connect the storage shelves to each other About NetBackup 5240 Appliance configurations To determine the right NetBackup 5240 Appliance system for your environment you should consider the env...

Page 8: ...This section describes the features and components of the NetBackup 5240 Appliance Table 1 1 NetBackup 5240 Appliance features Description Feature Red Hat Enterprise Linux 6 8 Operating system Two 2 Intel Xenon E5 2630 v3 2 40GHz processors Processor Version 3 0 or higher Note For the latest NetBackup Appliance compatibility information refer to the NetBackup Hardware Compatibility List posted on ...

Page 9: ...ber of disks Scalable architecture Supports the redundant hot swappable disks and power modules High availability RAID 1 standard mirroring and RAID 6 block level striping with double distributed parity are implemented as follows Appliance system disks RAID 1 Appliance storage disks RAID 6 Storage shelf data storage disks RAID 6 Note The disk drives in the appliance are pre formatted before the ap...

Page 10: ...time however you cannot operate the appliance if both disk drives are removed The disk drives in slot 2 and slot 3 are configured as the RAID1 VOLUME1 device These disk drives store all of the log files The disk drives in slots 4 through 10 store user data They are configured as a RAID 6 array which uses block level striping with two parity blocks across each of the disk drives in the volume The a...

Page 11: ...storage space Hot spare RAID 6 11 NetBackup 5240 Appliance disk drive LEDs Each disk drive module contains two LEDs on the left hand side of each module The LEDs appear as follows Figure 1 2 NetBackup 5240 Appliance disk drive module LEDs Amber Status LED Green Activity LED Table 1 3 NetBackup 5240 Appliance disk drive LEDs Indication Color Description Number No faults Disk fault RAID rebuild is i...

Page 12: ...oing on some colored lights may still be seen through the disk modules NetBackup 5240 Appliance front panel USB port The NetBackup 5240 Appliance front panel includes a USB 2 0 compliant port that supports a data transfer rate of up to 480 Mb second Figure 1 3 NetBackup 5240 Appliance front USB port NetBackup 5240 Appliance control panel The front panel of the NetBackup 5240 Appliance includes a s...

Page 13: ...ommends that you do not enable NMI by pressing the NMI button NMI button recessed tool required for use B The front control panel includes two activity LED indicators for each on board network interface controller NIC NIC 5 represents network interface controller 5 while NIC 6 represents network interface controller 6 When network links are detected on the controllers the LEDs are activated and re...

Page 14: ... LED E The Power Sleep button toggles the system on and off See Power button LED states on page 17 Power Sleep button with integrated LED F The drive activity LED on the front panel indicates drive activity from the on board hard disk controllers Hard Drive Activity LED G System Status LED states The System Status LED is a bi color Green Amber indicator that shows the current health of the system ...

Page 15: ...cal threshold crossed Temperature including HSBP temp voltage input power to power supply output current for main power rail from power supply and Processor Thermal Control Therm Ctrl sensors Power supply predictive failure occurred while redundant power supply configuration was present Unable to use all of the installed memory one or more DIMMs failed disabled but functional memory remains availa...

Page 16: ...rm Ctrl sensors VRD Hot asserted Minimum number of fans to cool the system not present or failed Hard drive fault Power Unit Redundancy sensor Insufficient resources offset indicates not enough power supplies present Correctable memory error threshold has been reached for a failing DIMM when the system is operating in a non redundant mode Non critical The system is operating in a degraded state wi...

Page 17: ...mily not identical Processor model not identical Processor core thread counts not identical Processor cache size not identical Unable to synchronize processor frequency Unable to synchronize QPI link frequency Critical non recoverable System is halted Solid on Amber Power button LED states The Power button is located on the NetBackup 5240 Appliance control panel It is used to turn the appliance on...

Page 18: ...r panel The rear panel of the appliance has several access ports and other features which are displayed in the following figures Figure 1 7 NetBackup 5240 Appliance rear panel overview 1 2 3 4 5 6 7 8 9 10 11 12 13 Table 1 7 NetBackup 5240 Appliance rear panel features and connectors Function Number Power Supply 1 and Power Supply 2 Dual redundant and hot swappable power supply modules 1 2 eth4 NI...

Page 19: ... card for VMware optimized deduplication over Fibre Channel or tape library connectivity In some configurations the Fibre Channel host bus adapter cards are installed into some of the PCIe slots If the cards are installed in slots 5 and 6 the configuration supports Fibre Transport Media Server FTMS mode Port 1 of each card is configured by default as Target while port 2 is configured by default as...

Page 20: ...ETH2 NIC3 ETH3 NIC4 NetBackup 5240 Appliance I O configuration options The rear panel of the NetBackup 5240 Appliance contains three PCIe riser card assemblies PCIe riser card assemblies 1 and 2 each support three standard PCIe cards while PCIe riser card assembly 3 supports two low profile PCIe cards The slots are labeled 1 to 8 Slots 1 2 and 3 are located in PCIe riser card assembly 2 Slots 4 5 ...

Page 21: ...e Table 1 8 Available NetBackup 5240 Appliance PCIe based I O configuration options Slot 8 Slot 7 Slot 6 Slot 5 Slot 4 Slot 3 Slot 2 Slot 1 I O configuration option A 8 Gb FC HBA 3 B 8 Gb FC HBA 3 10 GbE NIC 1 3 C 8 Gb FC HBA 3 8 Gb FC HBA 3 8 Gb FC HBA 3 10 GbE NIC 1 3 8 Gb FC HBA 3 D 8 Gb FC HBA 3 8 Gb FC HBA 3 8 Gb FC HBA 3 8 Gb FC HBA 3 8 Gb FC HBA 3 E 8 Gb FC HBA 3 1 GbE NIC 2 4 port RJ45 F 8...

Page 22: ...isk drives are located in slots 0 and 1 of the front panel Slot 8 is reserved for the optional SAS tape out adapter which is used to connect external SAS devices to the NetBackup 5240 Appliance PCIe card cable connection types 1 Direct Attach copper cable also called a Twinaxial cable or Twinax 2 Standard copper cable 3 Fiber optic cable I O configuration option notes A NetBackup 5240 Appliance us...

Page 23: ... 2 4 on board 0 2 2 C 8 4 on board 0 2 2 D 10 4 on board 0 2 E 2 8 total 4 on board 4 PCIe 0 0 2 F 2 4 on board 0 6 2 G 4 4 on board 2 2 2 H 2 4 on board 0 2 2 J 2 4 on board 0 4 2 K 2 8 total 4 on board 4 PCIe 0 2 2 L Cable connection types copper Standard copper cable optical fiber optic cable Dual port 10 Gb Ethernet card with SFP transceiver ports The 10Gb Ethernet card with SFP transceivers i...

Page 24: ...3 RH non operating non condensing Storage humidity PCIe v3 0 System interface type 8 0 GT s gigatransfers per second Speed and slot width Fibre Channel over Ethernet FCoE Network File System NFS Storage over Ethernet Optical 1GbE 10GbE Direct attach 10GbE Data rate supported per port LINK solid and ACTIVITY blinking LINK SPEED green 10Gbps yellow 1Gbps LED indicators FCC B UL CE VCCI BSMI CTICK KC...

Page 25: ...net FCoE and iSCSI traffic at 10Gbps Ethernet GbE line rate speeds The QLE8442 also provides very low host CPU usage by enabling full hardware offloads The QLE8442 dual port 10GbE is an iSCSI capable card that is available with configuration H of the NetBackup 5240 Appliance It supports the iSCSI protocol at 10Gb Ethernet 10GbE line rate The card provides iSCSI hardware offload which reduces CPU i...

Page 26: ...SPR KCC Certifications 0 to 55 C 32 TO 131 f Operating temperature 40 to 65 C 40 to 149 F Storage temperature 7 to 93 55 C Operational humidity 93 maximum at 65 C Storage humidity 100 LFM 55 C Air flow See NetBackup 5240 Appliance I O configuration options on page 20 QLE2562 dual port 8Gb Fibre Channel host bus adapter with SFP modules The QLE2562 dual port 8Gb Fibre Channel FC host bus adapter wi...

Page 27: ...perature 5 RH to 93 RH non operating non condensing and 5 RH to 93 RH operating non condensing Operating humidity PCIe v3 0 System interface type FCC B UL CE VCCI CISPR KN CNS Certifications OM3 OM2 OM1 Rate External connections 500m 300m 150m 2Gbps 380m 150m 70m 4Gbps 150m 50m 21m 8Gbps The following table describes the Fibre Channel host bus adapter LED indicator status activity 27 About the Net...

Page 28: ... alternately 4Gbps link input output I O activity On Blink Off Off 8Gbps link input output I O activity Off On Blink Off 16Gbps link input output I O activity Off Off On Blink See NetBackup 5240 Appliance I O configuration options on page 20 Quad port 1Gb Ethernet card with RJ45 connectors The quad port 1Gb Ethernet card with RJ45 connectors is available with the NetBackup 5240 Appliance The card ...

Page 29: ... Certifications 0 LFM Air Flow minimum 0 to 55 C 32 to 131 F Operating Temperature 40 to 70 C 40 to 158 F Storage Temperature 90 non condensing relative at 35 C Storage Humidity Maximum Typical Power consumption 6 watts 5 watts Speed 1Gbps SAS tape out adapter The SAS tape out adapter is used to connect external SAS devices to the NetBackup 5240 Appliance The adapter is available for use with all ...

Page 30: ...nnector 2 Connector 1 on the internal RAID controller connects to the appliance operating system and log file disk drives To purchase a SAS tape out adapter for your appliance contact your Veritas sales representative or your Veritas Partner representative NetBackup 5240 SAS tape out adapter Description SKU Number NETBACKUP APPLIANCE XXX0 APPLIANCE SAS3 SFF 8644 TO SAS3 SFF 8644 3M CABLE CRU CORPO...

Page 31: ...twork Interface Port locations eth4 NIC5 eth5 NIC6 eth0 NIC1 eth1 NIC2 eth2 NIC3 eth3 NIC4 IPMI Remote Management port Table 1 15 NetBackup 5240 Appliance Network Interface Port speeds 1Gb Ethernet copper 1Gb Ethernet 10Gb Ethernet copper eth0 NIC1 Note Veritas does not support forming a NIC bond using eth0 NIC1 with other eth NIC ports eth4 NIC5 eth1 NIC2 eth5 NIC6 eth2 NIC3 eth3 NIC4 IPMI port 3...

Page 32: ...nce and Veritas 2U12 49TB Storage Shelf connections Veritas 2U12 49TB Storage Shelf overview The optional Veritas 2U12 49TB Storage Shelf is a 2U12 drive enclosure that contains twelve 6TB 7200 rpm SAS hard disk drives Available storage capacity of the storage shelf is 49TBs Each disk drive can be accessed from the storage shelf s front panel An embedded RAID controller is used to configure the di...

Page 33: ...nclosure identification and a switch that is used for storage shelf configuration purposes The Veritas 2U12 49TB Storage Shelf serial number appears on a plastic panel on the left side of Power Cooling Module 0 PCM 0 The storage shelf serial number begins with the letters SH See Veritas 2U12 49TB Storage Shelf front panel components on page 34 See Veritas 2U12 49TB Storage Shelf rear components on...

Page 34: ...d as it may result in degraded performance Warning Failure to migrate MSDP data after you connect a storage shelf may result in degraded appliance throughput performance For more information about migrating MSDP data see the following document Moving the MSDP partition from a base disk to an expansion disk for optimum performance Veritas 2U12 49TB Storage Shelf front panel components Hard disk dri...

Page 35: ...rovides the status Table 2 2 Veritas 2U12 49TB Storage Shelf disk drive carrier LED status Fault amber LED Activity green LED Status OFF OFF No disk drive installed OFF Blinks during I O activity and during startup Drives are installed turned on and operational Blinks at a rate of 1 second ON and 1 second OFF ON SCSI Enclosure Services SES Device identity set ON OFF Drive slot fault ON ON Drive fa...

Page 36: ... bay must be unlocked using a T10 screw driver Veritas 2U12 49TB Storage Shelf control panel The Veritas 2U12 49TB Storage Shelf control panel is installed on the front left side of the storage shelf Figure 2 3 Veritas 2U12 49TB Storage Shelf control panel 1 3 4 5 2 36 About the Veritas 2U12 49TB Storage Shelf Veritas 2U12 49TB Storage Shelf control panel ...

Page 37: ...associated with the shelf s disk drives However the Logical Status LED can also indicate an issue with an internal RAID controller or external RAID controller or with a host bus adapter Logical status LED amber 4 The Unit Identification Display is a dual digit display that provides information about the storage shelf Its primary function is to assist in the configuration of multiple storage shelve...

Page 38: ... Module installed Invalid or Mixed Power Cooling Module Fault LEDs Fan Fault LEDs N A Flashing On Green Drive failure has occurred causing loss of availability or redundancy Array in a failed or degraded state On N A On Green Array operating background function Arrays in an impacted state Flashing N A On Green Enclosure ID setting different from start of day setting SES state S1 N A Flashing On N ...

Page 39: ...ower Cooling Module 0 PCM0 1 I O module 0 2 Power Cooling Module 1 PCM1 3 I O module 1 4 See Veritas 2U12 49TB Storage Shelf I O modules on page 39 See Veritas 2U12 49TB Storage Shelf Power Cooling Modules on page 43 See Power Cooling Module LEDs on page 45 Veritas 2U12 49TB Storage Shelf I O modules This section discusses the Veritas 2U12 49TB Storage Shelf I O modules 39 About the Veritas 2U12 4...

Page 40: ...e and table provides details of the two Veritas 2U12 49TB Storage Shelf I O module canisters Figure 2 6 Veritas 2U12 49TB Storage Shelf I O modules 1 2 4 3 3 5 5 6 6 C B A C B A 4 7 40 About the Veritas 2U12 49TB Storage Shelf Veritas 2U12 49TB Storage Shelf rear components ...

Page 41: ... on page 42 7 I O module Status LED location and conditions This section discusses the location of the Status LEDs on the I O module and the Status LED conditions Figure 2 7 I O module Status indicator LED location I O module Status LED location Table 2 7 I O module Status LED conditions Fault LED amber Activity LED green Condition The I O module has encountered a fault condition On Module Fault a...

Page 42: ...location and conditions This section discusses the location of the SAS Activity LEDs on the I O module and the SAS Activity LED conditions Figure 2 8 I O module SAS Activity LED location SAS Activity LED location Table 2 8 I O module SAS Activity LED conditions Fault LED amber Activity LED green Condition Off Off No Cable Present Off On Cable Present All links up no activity Off Flash with aggrega...

Page 43: ...example not all links established OVERTEMPERATURE condition detected See Veritas 2U12 49TB Storage Shelf I O modules on page 39 See I O module Status LED location and conditions on page 41 Veritas 2U12 49TB Storage Shelf Power Cooling Modules The Veritas 2U12 49TB Storage Shelf includes two Power Cooling Modules PCM The dual PCMs provide redundant power to the storage shelf If one PCM fails the st...

Page 44: ...wer Cooling Module components Component Number Power Cooling Module LEDs See Power Cooling Module LEDs on page 45 1 On Off switch 2 Release tab 3 AC power socket 4 44 About the Veritas 2U12 49TB Storage Shelf Veritas 2U12 49TB Storage Shelf rear components ...

Page 45: ...dule 0 tab Note The storage shelf serial number begins with the letters SH 5 Power Cooling Module LEDs Power Cooling Modules PCM use four LEDs to indicate the status of the PCM Figure 2 10 Power Cooling Module LEDs 1 3 2 4 45 About the Veritas 2U12 49TB Storage Shelf Veritas 2U12 49TB Storage Shelf rear components ...

Page 46: ...r this Power Cooling Module only Off Off Off On AC Present Power Cooling Module On OK On Off Off On Power Cooling Module fan out of tolerance Off Off On Off Power Cooling Module fan fail On On On Off Power Cooling Module Fault Over temp over volts over current Off Off Off Flashing Standby Mode Flashing Flashing Flashing Off Power Cooling Module firmware download See Veritas 2U12 49TB Storage Shelf...

Page 47: ...lves You can find detailed information about connecting the NetBackup 5240 Appliance to Veritas 2U12 49TB Storage Shelves in the NetBackup 5240 Appliance Hardware Installation Guide Figure 2 11 NetBackup 5240 Appliance and Veritas 2U12 49TB Storage Shelf cabling connections Note A 3 meter SAS 3 cable may be required to connect the sixth storage shelf to the appliance if your rack alignment differs...

Page 48: ...s Each of the AC power modules in the NetBackup 5240 Appliance and in the optional Veritas 2U12 49TB Storage Shelf accept one AC power cable One end of the AC power cable is connected to the power supply on the appliance or the storage device The other end of the cable is connected to an external Power Distribution Unit PDU on the rack Power cables include a live line a neutral line and a groundin...

Page 49: ...e meets or exceeds the indicated power rating See NetBackup 5240 Appliance and Veritas 2U12 49TB Storage Shelf technical specifications on page 54 Network cable The NetBackup appliance communicates with the Ethernet networks through an Ethernet network cable One end of the network cable connects to the management network port or service network port of the appliance The other end of the cable conn...

Page 50: ...cable One end of the multi mode fiber optic cable connects to the 10GbE service network port or the Fibre Channel port The other end of the cable connects to the Fibre Channel switch or other devices The two ends of the multi mode fiber optic cable are LC connectors Figure 3 3 Multi Mode fiber cable 50 NetBackup 5240 Appliance and Veritas 2U12 49TB Storage Shelf cables Multi Mode fiber optic cable...

Page 51: ...naxial copper cables The NetBackup 5240 Appliance communicates with Ethernet networks that run the iSCSI protocol through high speed Twinaxial copper cables If you configure the appliance to communicate with 10 Gb Ethernet iSCSI networks these cables connect to the iSCSI card in the appliance These cables are also known as Direct Access copper cables and are available in 1 meter 3 meter or 5 meter...

Page 52: ...al Veritas 2U12 49TB Storage Shelf to the NetBackup 5240 Appliance SAS 3 cables have a SAS 3 connector on both ends Two SAS 3 cables ship with each Veritas 2U12 49TB Storage Shelf 52 NetBackup 5240 Appliance and Veritas 2U12 49TB Storage Shelf cables SAS 3 cable ...

Page 53: ...Figure 3 4 SAS 3 cable 53 NetBackup 5240 Appliance and Veritas 2U12 49TB Storage Shelf cables SAS 3 cable ...

Page 54: ...NetBackup 5240 Appliance technical specifications The following table provides technical specifications for the NetBackup 5240 Appliance Table A 1 NetBackup 5240 Appliance technical specifications NetBackup 5240 Appliance Technical Specification 19 EIA standard The rack rails that are provided for the NetBackup 5240 Appliance are extensible to 36 914mm This distance is the maximum depth that is al...

Page 55: ...DR4 RDIMM 8 GB x 8 Memory type and configuration DIMMs Mezzanine card Yes PCIe RAID card Yes for storage capacities over 27 TB SAS RAID card installed in a PCIe riser assembly Y N 1 GB for the internal mezzanine RAID controller 1 GB is also included on the external PCIe RAID controller when the first storage shelf is purchased RAID cache Appliance 4 TB 14 TB 27 TB Each storage shelf 49 TB Maximum ...

Page 56: ...ents Specification IEC 60320 C14 to IEC 60320 C13 10A 250V Black 4 ft The IEC 60320 C14 plugs into a Power Distribution Unit The IEC 60320 C13 plugs into an appliance or storage shelf power supply Note If your power distribution unit is not compatible with the IEC 60320 C14 plug then Veritas recommends that you purchase your power cable locally Make sure the power cable meets or exceed the indicat...

Page 57: ...tts typical 819 BTU hr 500 watts maximum 1706 BTU hr System cooling requirement heat dissipation 10 185 BTU hr System cooling requirement with maximum external storage heat dissipation 100V 127 VAC 200V 240 VAC Operating voltage Appliance 90 Storage shelf 80 Power conversion efficiency Appliance 70 dBA Storage shelf 63 dBA Acoustic noise Veritas 2U12 49TB Storage Shelf technical specifications The...

Page 58: ...rage Bay Bridge SBB 2 1 Hot swappable components 49TB Usable storage capacity TB 28 kg 62 lbs Maximum weight fully populated 52 kg 115 lbs Shipping weight Height 8 89cm 3 5 approximately 2U Width 48 3cm 19 ICE rack compliant Depth 60 2cm 23 7 Dimensions Dual ported 12Gb s SAS drives Device types supported 12 Maximum drives per enclosure 225 watts per storage shelf You can connect a maximum of four...

Page 59: ... The following table lists the environmental specifications for the NetBackup 5240 Appliance and the Veritas 2U12 49TB Storage Shelf Table A 3 NetBackup 5240 Appliance and Veritas 2U12 49TB Storage Shelf environmental specifications NetBackup 5240 Appliance Veritas 2U12 49TB Storage Shelf Specification ASHRAE A2 10 C to 35 C 50 F to 95 F Operating temperature 25 C to 70 C 13 F to 158 F The non ope...

Page 60: ...lowing table provides standards with which the NetBackup 5240 Appliance and the Veritas 2U12 49TB Storage Shelf comply Table A 4 NetBackup 5240 Appliance Veritas 2U12 49TB Storage Shelf standards compliance Version Standard Intelligent Platform Management Interface Specification Second Generation v2 0 Document Revision 1 0 IPMI 2 0 System Management BIOS SMBIOS Reference Specification Version 2 5 ...

Page 61: ... is done using a server board with a microprocessor from the same family or higher and operating at the same or higher speed as the microprocessor that is used on this server board The final configuration of your appliance product may require additional EMC compliance testing This product is an FCC Class A device Integration of it into a Class B system does not result in a Class B device Product r...

Page 62: ...ltage Directive 73 23 EEE Europe IRAM Certification Argentina GB4943 CNCA Certification China Product EMC Compliance Class A Compliance The following is a list of EMC compliance norms for different countries FCC ICES 003 Emissions USA Canada Verification CISPR 22 Emissions International EN55022 Emissions Europe EN55024 Immunity Europe EN61000 3 2 Harmonics Europe EN61000 3 3 Voltage Flicker Europe...

Page 63: ... 0 01 by mass 100 PPM for Cadmium California Code of Regulations Title 22 Division 4 5 Chapter 33 Best Management Practices for Perchlorate Materials China Restriction of Hazardous Substances China RoHS WEEE Directive Europe Packaging Directive Europe Certifications Registrations Declarations The following is a list of the required certifications registrations and declarations NRTL Certification U...

Page 64: ...ver there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to a radio or a television reception can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation betwe...

Page 65: ...ve This digital apparatus does not exceed the Class A limits for radio noise emissions from the digital apparatus that is set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Canadian Department of Communications CE Declaration of Conformity Europe This product has been tested in accordance to and complies with the Low Voltage Directive 73 23 EEC and EM...

Page 66: ...l LED descriptions NetBackup 5240 Appliance 13 Veritas 2U12 49TB Storage Shelf 36 D DIMM system memory configuration 8 disk drive configurations NetBackup 5240 Appliance 10 disk drive LED indicators NetBackup 5240 Appliance 11 disk drive LEDs NetBackup 5240 Appliance 11 disk drive slots NetBackup 5240 Appliance 10 drive bay slot assignments Veritas 2U12 49TB Storage Shelf 34 E environmental specif...

Page 67: ...iance 17 descriptions 17 Power Cooling Modules PCM status LEDs Veritas 2U12 49TB Storage Shelf 45 Veritas 2U12 49TB Storage Shelf 43 processor type 8 protocol standards NetBackup 5240 Appliance Veritas 2U12 49TB Storage Shelf 60 Q QLE8442 dual port 10Gb Ethernet card dual port 25 R RAID configuration NetBackup 5240 Appliance 10 RAID levels 8 rear components Veritas 2U12 49TB Storage Shelf 38 rear ...

Page 68: ...helf continued front panel components 34 hard disk drive capacities 34 I O modules 39 LED location and conditions 41 SAS Activity LED location and conditions 42 overview 32 Power Cooling Modules PCM 43 rear components 38 68 Index ...

Reviews: