![VERITAS NetBackup 523 Installation Manuals Download Page 31](http://html.mh-extra.com/html/veritas/netbackup-523/netbackup-523_installation-manuals_1004860031.webp)
1
Peel the protective film from the top of the storage shelf.
2
Lift up one end of the storage shelf and peel the film from the bottom of the
chassis.
3
When approximately half of the film is removed, lift the other end of the storage
shelf and remove the remaining film.
4
Peel the film from the sides of the storage shelf.
5
Discard all of the film.
See “Installing the Storage Shelf guide rails” on page 31.
Installing the Storage Shelf guide rails
The Storage Shelf is shipped with left and right mounting rails. These rails install
in a standard 19-inch rack. The front plates of the rails are marked left and right.
Two-inch lips on the bottoms of the rails provide a shelf on which the storage system
sits. Extenders that are built into the rails let you adjust the rails for the depth of the
rack.
Caution:
Due to the weight of the units, Veritas recommends that storage shelves
be installed at or near the bottom of the rack.
Requirements
■
19-inch equipment rack
■
Available 3U slot
■
Six M5 screws (provided)
■
Six cage nuts (provided)
■
Number 2 Phillips screwdriver
■
Flashlight
31
Installing hardware into racks
Installing the Storage Shelf guide rails